Loading...
Vista Properties-LR 960809A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR: CENTEX HOMES DATE: 8/9/96 (F /K/A VISTA PARTNERS) DALLAS, TEXAS PROJECT: SANITARY SEWER AND WATER OUR REPORT NO IMPROVEMENTS COPPELL, TEXAS TEST DATA: 96562 -1 -A TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT' 1 08/09/96 FG - 2.0 4 18.5 102.5 19.6 98 96 1 -A 2 08/09/96 FG 4 18.5 102.5 20.8 98 95 1 -A 3 08/09/96 FG - 3.0 4 18.5 102.5 19.4 99 96 1 -A 4 08/09/96 FG - 2.0 4 18.5 102.5 19.0 99 96 1 -A 5 08/09/96 FG - 1.0 4 18.5 102.5 20.5 98 96 1 -A 6 08/09/96 FG 4 18.5 102.5 19.3 100 97 1 -A 7 08/09/96 FG - 2.0 4 18.5 102.5 20.1 98 95 1 -A TEST LOCATION: 1 8" WATER LINE "A" STA: 29 + 50 2 8" WATER LINE "A" STA: 29+60 3 8" WATER LINE "A" STA: 27+50 4 8" WATER LINE "A" STA: 27+40 5 8" WATER LINE "A" STA: 25+55 6 8" WATER LINE "A" STA: 25+45 7 8" WATER LINE "A" STA: 23+50 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED 0001083 -18 A. TEST RESULTS COMPLY WITH SPECIFICATIONS B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST Respectf ubmitted, AL ATE TING, INC. AVID, A ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (214) 620 -8911 REPORT OF FIELD COMPACTION TESTS TESTED FOR: CENTEX HOMES DATE: 8/9/96 (F /K/A VISTA PARTNERS) DALLAS, TEXAS PROJECT: SANITARY SEWER AND WATER OUR REPORT NO. IMPROVEMENTS COPPELL, TEXAS TEST DATA: 96562 -1 -B TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE i MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT` 8 08/09/96 FG 4 18.5 102.5 19.6 100 97 1 -A 9 08/09/96 FG - 1.0 4 18.5 102.5 20.3 98 95 1 -A 10 08/09/96 FG 4 18.5 102.5 19.9 98 96 1 -A TEST LOCATION: 8 8" WATER LINE "A" STA: 23 + 60 9 8" WATER LINE "A" STA: 21 + 50 10 8" WATER LINE "A" STA: 21 + 40 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED COO,093 -18 A. TEST RESULTS COMPLY WITH SPECIFICATIONS B. COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST Respectfu ubmifted, AL A TESTING, INC. A T