Loading...
Vistas of C P3-LR 990518FUGRO SOUTH, INC. ff§ R ■ 2880 Virgo Lane: Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: May 18 1999 PROJECT Vistas of Coppell 3, Coppell, Texas Project No.: 0781 -2276 SAMPLE DATE: April 16, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Site Concrete CONCRETE SUPPLIER: Lattimore PLANT/TRUCK: MIX ID NUMBER: AIR ( %) (ASTM C -231) : WATER ADDED (gal): SLUMP (in .) (ASTM C -143) : Pavement: inlet tops on Park Highland Drive, station 7 +25 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER NUMBER AGE (days) DATE TESTED LOAD (pounds) STRENGTH (psi) STRENGTH (psi) VOC 81 7 4 -23-99 149000 5270 3000/28 days VOC 82 28 5 -14 -99 164000 5800 VOC 83 28 5 -14 -99 167000 5550 VOC 84 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Curing: Testing ASTM C -143, Types of Methods: ASTM C -39 Fracture: A® B® C Z D REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed to be correct. Technician: Frank Daniel FUGRO SOUTH INC. Reviewed By: SMH /em Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis �