Loading...
Vistas of C P3-LR 990513FUGRO SOUTH, INC. r � 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 4848301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: May 13 1999 PROJECT Vistas of Coppell 3, Coppell, Texas Project No .: 0781 -2276 SAMPLE DATE: April 15, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Humphrey and Morton 3082000 CONCRETE SUPPLIER: Lattimore Materials 64 PLANT/TRUCK: 4/822 66 MIX ID NUMBER: 42/3600 2:21 AIR ( %) (ASTM C -231) : 4.7 3:15 WATER ADDED (gal): 10 Sunny SLUMP (in .) (ASTM C -143) : 4 Pavement on inlets, 1 st one on the right heading east on Lyndsie Drive from Natches Trace. 7 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) VOC 77 7 4 -22 -99 122000 4320 3600/28 days VOC 78 28 5 -13 -99 157000 5550 VOC 79 28 5 -13 -99 154000 5450 VOC 80 Hold Fracture mode is (A) unless otherwise noted Specifications: & ASTM C -31 ® ® Z Curing: Methods: ASTM C -39 Fractu of A B C D REMARKS: Technician: Frank Daniel SMH /rm Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis / FUGRO SOUTH INC. Reviewed By: _