Vistas of C P3-LR 990430GRO
FUGRO SOUTH, INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484 -8301; Fax (972) 620 -7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Centex Homes Report Date: April 30, 1999
PROJECT: Vistas of Coppell 3, Coppell, Texas Project No.: 0781 -2276
SAMPLE DATE: April 22, 1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. (°F):
CONCRETE TEMP. ( °F) (ASTM C- 1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Site Concrete
CONCRETE SUPPLIER: Lattimore
PLANT/TRUCK:
MIX ID NUMBER:
AIR ( %) ( ASTM C -231)
WATER ADDED (gal):
Clear SLUMP (in.) (ASTM C -143) :
Pavement on inlet at Lyndsie Drive and Springhill Drive
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12 ", 28.27 square inches
TOTAL
COMPRESSIVE
SPECIFIED COMPRESSIVE
CYLINDER
AGE
DATE
LOAD
STRENGTH
STRENGTH
NUMBER
(days)
TESTED
(pounds)
(psi)
(psi)
VOC 85
7
04/29/99
89000
3150
3000/28 days
VOC 86
28
05/20/99
VOC 87
28
05/20/99
VOC 88
Hold
Fracture mode is (A) unless otherwise noted
Specifications:
Making & ASTM C -31
Testing ASTM C -143,
Types of
Z
Curing:
Methods: ASTM C -39
Fracture: A® B® C D
REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed
to be correct.
Technician: David Putman
FUGRO SOUTH INC.
Reviewed By:
SMH /rm
Distribution: Centex Homes - Robert Poole
City of Coppell - Larry Davis i
FUGRO SOUTH, INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484 -8301: Fax (972) 620 -7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Centex Homes
PROJECT Vistas of Coppell 3, Coppell, Texas
Report Date: April 30, 1999
Project No.: 0781 -2276
SAMPLE DATE: April 1, 1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. (°F):
CONCRETE TEMP. ( °F) (ASTM C- 1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Gilco Contractors, Inc.
7068334
CONCRETE SUPPLIER:
Lattimore
70
PLANTITRUCK:
7/785
69
MIX ID NUMBER:
438
12:01
AIR ( %) (ASTM C -231) :
4.5
12:37
WATER ADDED (gal):
10
Cloudy
SLUMP (in.) (ASTM C -143) :
4.50
Pavement on
Lyndsie Drive
VOC 37
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12 ", 28.27 square inches
TOTAL
COMPRESSIVE
SPECIFIED COMPRESSIVE
CYLINDER
AGE
DATE
LOAD
STRENGTH
STRENGTH
NUMBER
(days)
TESTED
(pounds)
(psi)
(psi)
VOC 37
7
04/08/99
114000
4030
3000/28 days
VOC 38
28
04/29/99
166000
5870
VOC 39
28
04/29/99
168000
5940
VOC 40
Hold
Fracture mode is (A) unless otherwise noted
Specifications:
Making & ASTM C -31
Testing ASTM C -143,
Types of
Fracture: Z
Curing:
Methods: ASTM C -39
A® B C D
REMARKS:
Technician: Frank Daniel
FUGRO SOUTH INC.
Reviewed By: —� -
SMH /rm
Distribution: Centex Homes - Robert Poole
City of Coppell - Larry Davis
FUGRO SOUTH, INC.
fsRO
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484 -8301; Fax (972) 620 -7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Centex Homes
PROJECT: Vistas of Coppell 3, Coppell, Texas
Report Date: April 30, 1999
Project No.: 0781 -2276
SAMPLE DATE: April 1, 1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. ( °F):
CONCRETE TEMP. ( °F) (ASTM C- 1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Gilco Contractors, Inc.
14091638
CONCRETE SUPPLIER:
Lattimore
68
PLANT/TRUCK:
14/622
65
MIX ID NUMBER:
438
2:24
AIR ( %) (ASTM C -231) :
4.1
3:30
WATER ADDED (gal):
0
Cloudy
SLUMP (in.) (ASTM C -143) :
3
Pavement on Lyndsie Drive at station 6 +75
(psi)
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12 ", 28.27 square inches
TOTAL
COMPRESSIVE
SPECIFIED COMPRESSIVE
CYLINDER
AGE
DATE
LOAD
STRENGTH
STRENGTH
NUMBER
(days)
TESTED
(pounds)
(psi)
(psi)
VOC 41
7
04/08/99
112000
3960
3000/28 days
VOC 42
28
1 04/29/99
149000
5270
VOC 43
28
04/29/99
147000
5200
VOC 44
Hold
Fracture mode is (A) unless otherwise noted
Specifications:
Making & ASTM C -31
Testing ASTM C -143,
Types of
0 Z
Curing:
I Methods: ASTM C -39
Fracture: A® B C D
REMARKS:
Technician: Frank Daniel
FUGRO SOUTH INC.
Reviewed By: c
SMH /rm
Distribution: Centex Homes - Robert Poole
City of Coppell - Larry Davis
FUGRO SOUTH, INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph(972)484-8301; Fax(972)620-7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Centex Homes Report Date: April 30, 1999
PROJECT: Vistas of Coppell 3, Coppell, Texas Project No.: 0781 -2276
SAMPLE DATE: April 1, 1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. (°F):
CONCRETE TEMP. ( °F) (ASTM C- 1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Gilco Contractors, Inc.
7068298
CONCRETE SUPPLIER:
Lattimore
64
PLANTITRUCK:
7/959
66
MIX ID NUMBER:
438
8:01
AIR ( %) (ASTM C -231) :
4.2
8:45
WATER ADDED (gal):
10
Cloudy
SLUMP (in.) (ASTM C -143) :
3
Pavement on
Lyndsie Drive at station 13 +50
VOC 33
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12 ", 28.27 square inches
TOTAL
COMPRESSIVE
SPECIFIED COMPRESSIVE
CYLINDER
AGE
DATE
LOAD
STRENGTH
STRENGTH
NUMBER
(days)
TESTED
(pounds)
(psi)
(psi)
VOC 33
7
04/08/99
117000
4140
3000/28 days
VOC 34
28
04/29/99
153000
5410
VOC 35
28
04/29/99
150000
5310
VOC 36
Hold
Fracture mode is (A) unless otherwise noted
Specifications:
Making & ASTM C -31
Testing ASTM C -143,
Types of
Z
Curing:
Methods: ASTM C -39
Fracture: A® B® C D
REMARKS:
Technician: Frank Daniel
FUGRO SOUTH INC.
Reviewed By:
SMH /rm
Distribution: Centex Homes - Robert Poole
City of Coppell - Larry Davis