Vistas of C P3-LR 990429FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph(972)484 -8301; Fax(972)620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: April 29, 1999 PROJECT: Vistas of Coppell 3, Coppell, Texas Project No.: 0781 -2276 SAMPLE DATE: March 31, 1999 ( CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Gilco Contractors, Inc. 6094063 CONCRETE SUPPLIER: Lattimore Materials 54 PLANT/TRUCK: 6/808 60 MIX ID NUMBER: 438 6:41 AIR ( %) (ASTM C -231) : 4 7:30 WATER ADDED (gal): 0 Cloudy SLUMP (in.) (ASTM C-143): 31/4 Pavement on Park Highland Drive, station 6 +71.70 VOC 21 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) VOC 21 7 04/07/99 124000 4390 3000/28 days VOC 22 28 04/28/99 146000 5160 VOC 23 28 04/28/99 149000 5270 VOC 24 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Fracture: Curing: Methods: ASTM C -39 A® a® C D REMARKS: Technician: Frank Daniel FUGRO SOUTH INC. Reviewed By: L SMH /em Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis / FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes PROJECT: Vistas of Coppell 3, Coppell, Texas Report Date: April 29, 1999 Project No.: 0781 -2276 SAMPLE DATE: March 31, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM c- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Gilco Contractors 6094080 CONCRETE SUPPLIER: Lattimore 58 PLANT/TRUCK: 6/963 65 MIX ID NUMBER: 438 8:33 AIR ( %) (ASTM C-231): 4.1 9:30 WATER ADDED (gal): 0 Cloudy SLUMP (in.) (ASTM C -143) : 3 Pavement on Park Highland Drive, station 5 +00 VOC 25 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) VOC 25 7 04/07/99 138000 4880 3000/28 days VOC 26 28 04/28/99 165000 5840 VOC 27 28 04/28/99 163000 5770 VOC 28 Hold Fracture mode is (A) unless otherwise noted [Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Fracture: Curing: Methods: ASTM C -39 A® BE co D REMARKS: Technician: Frank Daniel FUGRO SOUTH INC. Reviewed By: 4 SMH /em Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis