Vistas of C P3-LR 990419FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date April 19, 1999 PROJECT: Vistas of Coppell 3, Copped, Texas Project No.: 0781 -2276 SAMPLE DATE: March 31, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Gilco Contractors 6094111 CONCRETE SUPPLIER: Lattimore 60 PLANT/TRUCK: 6/617 65 MIX ID NUMBER: 438 11:56 AIR ( %) (ASTM C -231) : 4.2 1:00 WATER ADDED (gal): 20 Cloudy SLUMP (in .) (ASTM C -143) : 3 Pavement on alley between Park Highland Drive and Springhill Drive, station 5 +40 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) VOC 29 7 04/07/99 125000 4420 3000/28 days VOC 30 28 04/28/99 153000 5410 VOC 31 28 04/28/99 156000 5520 VOC 32 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Fracture: 0 Curing: Methods: ASTM C -39 A® B® C D REMARKS: Technician: Frank Daniel FUGRO SOUTH INC. Reviewed By: SMH /em Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis FUGRO SOUTH, INC. C 1 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 4848301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes PROJECT Vistas of Coppell 3, Coppell, Texas Report Date April 19, 1999 Project No.: 0781 -2276 F SAMPLE DATE: Apirl 9, 1999 J CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: 7068895 CONCRETE SUPPLIER: Lattimore 78 PLANTITRUCK: 7-752 84 MIX ID NUMBER: 42 11:50 AIR ( %) (ASTM C -231) : LOAD (pounds) 12:20 WATER ADDED (gal): 15 Sunny SLUMP (in .) (ASTM C -143) : 5 Pavement at Park Highlands Drive, Station 8 +00 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER NUMBER AGE (days) DATE TESTED LOAD (pounds) STRENGTH (psi) STRENGTH (psi) VOC 73 7 4 -16 -99 108000 3820 3600/28 days VOC 74 28 5 -7 -99 VOC 75 28 5 -7 -99 VOC 76 Hold Specifications: Curing: ASTM C -31 Methods: ASTM C -39 Fracture mode is (A) unless otherwise noted F�u of A ® B C z D REMARKS: Technician: Mike Flute FUGRO SOUTH INC. Reviewed By: SMH /kp Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis � Gilco Contracting — Dale Gilreath