Vistas of C P3-LR 990419FUGRO SOUTH, INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484 -8301; Fax (972) 620 -7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Centex Homes Report Date April 19, 1999
PROJECT: Vistas of Coppell 3, Copped, Texas Project No.: 0781 -2276
SAMPLE DATE: March 31, 1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. ( °F):
CONCRETE TEMP. ( °F) (ASTM C- 1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Gilco Contractors
6094111 CONCRETE SUPPLIER: Lattimore
60 PLANT/TRUCK: 6/617
65 MIX ID NUMBER: 438
11:56 AIR ( %) (ASTM C -231) : 4.2
1:00 WATER ADDED (gal): 20
Cloudy SLUMP (in .) (ASTM C -143) : 3
Pavement on alley between Park Highland Drive and Springhill Drive,
station 5 +40
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12 ", 28.27 square inches
TOTAL
COMPRESSIVE
SPECIFIED COMPRESSIVE
CYLINDER
AGE
DATE
LOAD
STRENGTH
STRENGTH
NUMBER
(days)
TESTED
(pounds)
(psi)
(psi)
VOC 29
7
04/07/99
125000
4420
3000/28 days
VOC 30
28
04/28/99
153000
5410
VOC 31
28
04/28/99
156000
5520
VOC 32
Hold
Fracture mode is (A) unless otherwise noted
Specifications:
Making & ASTM C -31
Testing ASTM C -143,
Types of
Fracture: 0
Curing:
Methods: ASTM C -39
A® B® C D
REMARKS:
Technician: Frank Daniel
FUGRO SOUTH INC.
Reviewed By:
SMH /em
Distribution: Centex Homes - Robert Poole
City of Coppell - Larry Davis
FUGRO SOUTH, INC.
C 1
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 4848301; Fax (972) 620 -7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Centex Homes
PROJECT Vistas of Coppell 3, Coppell, Texas
Report Date April 19, 1999
Project No.: 0781 -2276
F SAMPLE DATE: Apirl 9, 1999 J
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. (°F):
CONCRETE TEMP. (°F) (ASTM C- 1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
7068895
CONCRETE SUPPLIER:
Lattimore
78
PLANTITRUCK:
7-752
84
MIX ID NUMBER:
42
11:50
AIR ( %) (ASTM C -231) :
LOAD
(pounds)
12:20
WATER ADDED (gal):
15
Sunny
SLUMP (in .) (ASTM C -143) :
5
Pavement at Park Highlands Drive, Station 8 +00
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12 ", 28.27 square inches
TOTAL
COMPRESSIVE
SPECIFIED COMPRESSIVE
CYLINDER
NUMBER
AGE
(days)
DATE
TESTED
LOAD
(pounds)
STRENGTH
(psi)
STRENGTH
(psi)
VOC 73
7
4 -16 -99
108000
3820
3600/28 days
VOC 74
28
5 -7 -99
VOC 75
28
5 -7 -99
VOC 76
Hold
Specifications:
Curing: ASTM C -31
Methods: ASTM C -39
Fracture mode is (A) unless otherwise noted
F�u of A ® B C z D
REMARKS:
Technician: Mike Flute
FUGRO SOUTH INC.
Reviewed By:
SMH /kp
Distribution: Centex Homes - Robert Poole
City of Coppell - Larry Davis �
Gilco Contracting — Dale Gilreath