Vistas of C P3-LR 990412FUGRO SOUTH, INC. Ono 2880 Virgo Lane; DaNas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: April 12, 1999 PROJECT: Vistas of Coppell 3, Coppell, Texas Project No.: 0781 -2276 SAMPLE DATE: April Z, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM c- 1os4): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Rodman / Gilco Contracting 7068462 CONCRETE SUPPLIER: Lattimore 70 PLANT/TRUCK: 7/757 67 MIX ID NUMBER: 42 9:56 AIR ( %) (ASTM C -231) : 4.50 10:51 WATER ADDED (gal): 0 Partly cloudy SLUMP (in.) (ASTM C443): 3 Paving: On Lyndsie, station 3 +20 (psi) CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6 " x 12". 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) VOC 45 7 04/09/99 116000 4100 3600/28 days VOC 46 28 04/30/99 VOC 47 28 04/30/99 VOC 48 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Testing ASTM C -143, Types of Curing: Methods: ASTM C -39 Fracture: A® B C D REMARKS: Technician: Pompey McGee FUGRO SOUTH INC. Reviewed By: SMH /rm Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis