Loading...
Vistas of C P3-LR 990326FUGRO SOUTH, INC. t>iR0 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301: Fax (972) 620 -7328 FIELD DENSITY REPORT CLIENT: Centex Homes REPORT DATE: March 26, 1999 PROJECT: Vistas of Coppell 3, Coppell, Texas PROJECT NO.: 0781 -2276 Page 1 DATE. PERFORMED: March 22,1999 Density Test Method: ASTM D -2922 & 3017 Method of Compaction: ASTM D-698 MOISTURE/DENSITY RELATIONS Material Proctor Results Number Description Maximum Dry Density (pct) Optimum Moisture (%) 1 Medium brown sand clay (lime treated) 103.3 19.3 2 Dark brown clay (lime treated) 97.6 23.3 TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY 191 1 Lime treated subgrade, Lyndsie Drive, 105.1 20.9 101.7 east bound lane, Station 1+44, final 192 1 Lime treated subgrade, Lyndsie Drive, 103.7 20.2 100.4 west bound lane, Station 4 +50, final 193 2 Lime treated subgrade, Lyndsie Drive, 93.9 25.1 96.1 centerline of lane, Station 7 +50, final 194 2 Lime treated subgrade, Lyndsie Drive, 97.6 23.1 100.0 west bound lane, Station 10 +50, final 195 1 Lime treated subgrade, Lyndsie Drive, 101.7 20.9 98.5 centerline of lane, Station 13 +50, final 196 2 Lime treated subgrade, Park Highlands 95.0 22.8 97.3 Drive, south bound lane, Station 1+39, final 197 2 Lime treated subgrade, Park Highlands 92.8 23.0 95.1 Drive, north bound lane, Station 4 +50, final 198 2 Lime treated subgrade, Park Highlands 97.5 23.7 99.9 Drive, south bound lane, Station 7 +50, final 199 2 Lime treated subgrade, Park Highlands 96.9 22.8 99.3 Court, centerline cul-de -sac, Station 1 +50, final 200 2 Lime treated subgrade, Alleyway C, 97.6 22.4 100.0 centerline, Station 1 +50, final 201 2 Lime treated subgrade, Alleyway C, north 93.9 24.1 96.2 bound, Station 4 +50, final FUGRO SOUTH, INC. Una 2880 Virgo lane; Dallas, Texas 75229 Ph (972) 484 -8301: Fax (972) 620 -7328 FIELD DENSITY REPORT CLIENT: Centex Homes REPORT DATE: March 26 1999 PROJECT: Vistas of Coppell 3, Coppell, Texas PROJECT NO.: 0781 -2276 Page 2 DATE PERFORMED: II lmh = 1999- TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY 202 2 Lime treated subgrade, Alleyway C, east 98.4 23.0 100.8 bound, Station 7 +50, final 203 1 Lime treated subgrade, Alleyway C, south 103.2 20.1 100.0 bound, Station 10 +50, final 204 2 Lime treated subgrade, Spring Hill Drive, 93.2 22.7 95.8 centerline, Station 1+50, final 205 2 Lime treated subgrade, Spring Hill Drive, 94.2 22.8 96.8 centerline, Station 4 +50, final 206 2 Lime treated subgrade, Spring Hill Drive, 95.6 22.8 98.2 east bound, Station 7 +50, final 207 2 Lime treated subgrade, Alleyway B, north 95.0 22.5 97.6 bound lane, Station 1+50, final 208 2 Lime treated subgrade, Alleyway B, 93.1 22.7 95.7 centerline, Station 4+00, final 209 1 Lime treated subgrade, Alleyway A, east 102.5 17.9 99.2 bound lane, Station 1 +00, final 210 2 Lime treated subgrade, Alleyway A, west 93.4 21.7 96.0 bound lane, Station 3 +50, final Remarks: All densities meet project specifications unless otherwise noted. Bob Shea Fugro South Technician FUGRO SOUTH INC. Reviewed by: �• ' 7'�"'`�' SMHIem Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis Giico Contracting :fu ano FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: March 26, 1999 PROJECT: Vistas of Coppell 3, Coppell, Texas Project NO.: 0781 -2276 SAMPLE DATE: February 25, 1999 1 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM c- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Technician: Jose Rivera Humphrey & Morton 169645 CONCRETE SUPPLIER: Pioneer PLANT/TRUCK: 271758 MIX ID NUMBER: 9339 AIR ( %) ( ASTM C -231) : WATER ADDED (gal): SLUMP (in.) (ASTM C-143): Inlets walls at Park Highlands Drive, station 2 +00 and station 2 +50 FUGRO SOUTH INC. Reviewed By: SMH /rrn Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis REMARKS: Cylinders cast by Contractor. All information except test data tumisnea Dy k.onirac►vi ai lu 00oul I to be correct.