Vistas of C P3-LR 990318FUGRO SOUTH, INC.
m
2880 Virgo lane; Dallas. Texas 75229
Ph (972) 484 -8301; Fax (972) 620 -7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Centex Homes
PROJECT Vistas of Coppell 3, Coppell, Texas
Report Date: March 18, 1999
Project No.: 0781 -2276
SAMPLE DATE: February 17,:1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. ( °F):
CONCRETE TEMP. ( °F) (ASTM C- 7os4):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
MB Structures Inc.
7065899
CONCRETE SUPPLIER:
Lattimore
65
PLANT/TRUCK:
7/752
77
MIX ID NUMBER:
38
1:57
AIR ( %) (ASTM C -231) :
LOAD
2:45
WATER ADDED (gal):
15
Clear
SLUMP (in.) (AsTM c - i43) :
4.5
Box culvert, west wall, west of intersection of Lyndsie and Waterview
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6 "'x 12 ", 28.27 square : inches
TOTAL
COMPRESSIVE
SPECIFIED COMPRESSIVE
CYLINDER
AGE
DATE
LOAD
STRENGTH
STRENGTH
NUMBER
(days)
TESTED
(pounds)
(psi)
(psi)
VOC 5
7
2 -24 -99
83000
2935
3000/28 days
VOC 6
28
3 -17 -99
115000
4070
VOC 7
28
3 -17 -99
113000
4000
VOC 8
Hold
Fracture mode is (A) unless othervAse noted
Specifications:
Cu king & ASTM G31
® z
Methods: ASTM C -39
Fracture: A BE c Do
REMARKS:
Technician: Ted Nicholas
FUGRO SOUTH INC.
Reviewed By: �r
SMH /em
Distribution: Centex Homes - Robert Poole
City of Coppell - Lary Davis
M B Structures
FUG SOUTH, INC.
r �
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484 -8301; Fax (972) 620 -7328
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Centex Homes
PROJECT Vistas of Coppell 3, Coppell, Texas
Report Date March 18, 1999
Project No.: 0781 -2276
SAMPLE DATE: February 25 1999
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. ( °F):
CONCRETE TEMP. ( ° F) (ASTM C- 1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
Humphrey & Morton
169645 CONCRETE SUPPLIER: Pioneer
PLANTf TRUCK: 27/758
MIX ID NUMBER: 9339
AIR ( %) (ASTM C -231)
WATER ADDED (gal):
SLUMP (in.) (ASTM C -143) :
Inlets walls at Park Highlands Drive, station 2 +00 and station 2 +50
CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12", 26.27 square inches
TOTAL
COMPRESSIVE
SPECIFIED COMPRESSIVE
CYLINDER
AGE
DATE
LOAD
STRENGTH
STRENGTH
NUMBER
(days)
TESTED
(pounds)
(psi)
(psi)
VOC 17
20
03/17/99
110000
3890
3500/28 days
VOC 18
28
03/25199
VOC 19
28
03/25/99
VOC 20
Hold
Fracture mode is (A) unless otherwise noted
Specifications:
& ASTM G31
® a
Curing:
Methods: ASTM C-39
Fractu of A 13 C D
REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed
to be correct.
Technician: Jose Rivera
FUGRO SOUTH INC.
Reviewed By:
SMH /m1
Distribution: Centex Homes - Robert Poole
City of Coppell - Larry Davis;'