Loading...
Vistas of C P3-LR 990318FUGRO SOUTH, INC. m 2880 Virgo lane; Dallas. Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes PROJECT Vistas of Coppell 3, Coppell, Texas Report Date: March 18, 1999 Project No.: 0781 -2276 SAMPLE DATE: February 17,:1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM C- 7os4): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: MB Structures Inc. 7065899 CONCRETE SUPPLIER: Lattimore 65 PLANT/TRUCK: 7/752 77 MIX ID NUMBER: 38 1:57 AIR ( %) (ASTM C -231) : LOAD 2:45 WATER ADDED (gal): 15 Clear SLUMP (in.) (AsTM c - i43) : 4.5 Box culvert, west wall, west of intersection of Lyndsie and Waterview CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6 "'x 12 ", 28.27 square : inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) VOC 5 7 2 -24 -99 83000 2935 3000/28 days VOC 6 28 3 -17 -99 115000 4070 VOC 7 28 3 -17 -99 113000 4000 VOC 8 Hold Fracture mode is (A) unless othervAse noted Specifications: Cu king & ASTM G31 ® z Methods: ASTM C -39 Fracture: A BE c Do REMARKS: Technician: Ted Nicholas FUGRO SOUTH INC. Reviewed By: �r SMH /em Distribution: Centex Homes - Robert Poole City of Coppell - Lary Davis M B Structures FUG SOUTH, INC. r � 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes PROJECT Vistas of Coppell 3, Coppell, Texas Report Date March 18, 1999 Project No.: 0781 -2276 SAMPLE DATE: February 25 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( ° F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Humphrey & Morton 169645 CONCRETE SUPPLIER: Pioneer PLANTf TRUCK: 27/758 MIX ID NUMBER: 9339 AIR ( %) (ASTM C -231) WATER ADDED (gal): SLUMP (in.) (ASTM C -143) : Inlets walls at Park Highlands Drive, station 2 +00 and station 2 +50 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 26.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) VOC 17 20 03/17/99 110000 3890 3500/28 days VOC 18 28 03/25199 VOC 19 28 03/25/99 VOC 20 Hold Fracture mode is (A) unless otherwise noted Specifications: & ASTM G31 ® a Curing: Methods: ASTM C-39 Fractu of A 13 C D REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed to be correct. Technician: Jose Rivera FUGRO SOUTH INC. Reviewed By: SMH /m1 Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis;'