Loading...
Vistas of C P3-LR 990316FUGRO SOUTH, INC. r - � 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes PROJECT Vistas of Coppell 3, Coppell, Texas Report Date March 16, 1999 Project No.: 0781 -2276 SAMPLE DATE: F ebruary 15, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( CONCRETE TEMP. ( °F) (ASTM C - 1064) TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: N B Structures 7065678 CONCRETE SUPPLIER: Lattimore 6 +3 PLANTITRUCK: 7/602 70 MIX ID NUMBER: 38 12:42 AIR ( %) (ASTM C -231) : 5 1:30 WATER ADDED (gal): 0 Partly Cloudy SLUMP (in .) (ASTM C.143): 5 Box culvert footing, Lyndsie Dr., Station 14 +20, Paving station C. NCRM. CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12' 28.27 square inches .......... -. . TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH (psi) NUMBER d TESTED (pounds) (psi) VOC 1 7 2 -22 -99 86000 3042 3000/28 days VOC 2 28 3 -15 -99 103000 3643 VOC 3 28 3 -15 -99 101000 3572 VOC 4 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM G31 Meth ® ® Z D Curing: ASTM C-39 Fracture: A S C REMARKS: Technician: Burl Cooper FUGRO SOUTH INC. Reviewed By: SMH /em Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis M B Structures