Vistas of C P3-LR 990226FUGRO SOUTH, INC. FIELD DENSITY REPORT fsRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 4848301; Fax (972) 620 -7328 CLIENT: Centex Homes REPORT DATE: February 26, 1999 PROJECT: Vistas of Coppell 3, Coppell, Texas PROJECT NO.: 0781 -2276 DATE PERFORMED: February 19, 1999 Density Test Method: ASTM D -2922 & 3017 Method of Compaction: ASTM D-698 MOISTURE/DENSITY RELATIONS Material Proctor Results Number Description Maximum Dry Density (pcf) Optimum Moisture ( %) 1 Medium brown silty sandy clay with some gravel 106.6 18.3 TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY 183 1 18 inch Storm Line SDI, Station 5 +50, 103.6 18.7 97.2 Leyndice Drive, 1 foot below grade 184 1 21 inch Storm Line SDI, Alley A, Block B, 100.8 21.3 95.0 Station 1 +00, 1 foot below grade 185 1 18 inch Storm Line SDI, Alley A, Block B, 103.9 19.6 97.5 Station 3 +50, 1 foot below grade 186 1 21 inch Storm Line SD2, Station 0 +40, 1 103.4 18.1 97.0 foot below grade 187 1 18 inch Storm Line SD2, Alley C, Block A, 102.9 21.2 96.5 Station 0 +80, 1 foot below grade Remarks: All densities meet project specifications unless otherwise noted. Burl Cooper Fugro South Technician FUGRO SOUTH INC. Reviewed by: SMH /em Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis Legends Construction FUGRO SOUTH, INC. r i 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: February 26, 1999 PROJECT: Vistas of Coppell 3, Coppell, Texas Project No.: 0781 -2276 SAMPLE DATE: February 17, 1999 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. ( °F) (AsTM c- 1o64): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: MB Structures Inc. 7065899 CONCRETE SUPPLIER: Lattimore 65 PLANT/TRUCK: 7/752 77 MIX ID NUMBER: 38 1:57 AIR ( %) (ASTM C -231) : LOAD 2:45 WATER ADDED (gal): 15 Clear SLUMP (in.) (ASTM C -143) : 4.5 Box culvert, west wall, west of intersection of Lyndsie and Waterview CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) VOC 5 7 2 -24 -99 83000 2935 3000/28 days VOC 6 28 1 3 -17 -99 VOC 7 28 3 -17 -99 VOC 8 Hold Fracture mode is (A) unless otherwise noted Sp ecifications: Making & ASTM C -31 Testing ASTM C -143, Types of Curing: Methods: ASTM C -39 Fracture: A® B® C D REMARKS: Technician: Ted Nicholas FUGRO SOUTH INC. Reviewed By: Z7 SMH /mv Distribution: Centex Homes - Robert Poole City of Coppell - Larry Davis M B Structures