Loading...
St Ann Catholic-LR070117CONCRETE COMPRESSIVE STRENGTH TEST Irerracon Report Number: 94061334.0029 Service Date: November 21, 2006 Dall Carpenter Fnvy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: January 17, 2007 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 94061334 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 8:05 AM Plant: 7 Supplier: Lattimore Materials Co Truck No: 7024 Ticket No: 7173450 Mix I.D. No.: 1701 Water Added Onsite Before Test: 10 Gallons Water Added Onsite After Test: 0 Gallons Sample Information Date Cast: November 21, 2006 Time: 8:50 AM Sampled by: Ira S. Haynes Weather Conditions: Clear Accumulative Yards: 90/130 Placement Method: Direct Discharge Sample Locations: 15' E & 130' N of NE corner of building Placement Location: Parking Lot Area for back side parking Field Test Data Test Result Specification Test Metho Slump, inches: 4.75 - ASTM C143 Air Content, %: 4.0 - ASTM C231 Concrete Temperature, oF: 67 - ASTM C1O64 Ambient Temperature,oF: 63 ASTM C 106 Plastic Unit Weight, pcf: N/A ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) ( sq. inches Tested (days (Ibs) (psi) 1 1 6.00 28.27 11/28/2006 7 116,830 4,130 1 2 6.00 28.27 12/19/2006 28 142,610 5,040 1 3 6.00 28.27 12/19/2006 28 144,330 5,100 Average (28 Days) 5,070 1 4 6.00 28.27 01/16/2007 56 159,7 5,650 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Ira S. Haynes Report Distribution: (1) St Ann Catholic Church (1) Tech niStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: 11 6 V L (1) City of Coppell TX Bulent Ethem, P.G. (1) Page Southerland Page A. Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01 PORR01- FO—Ney