Coppell Trade 2-LR061207~ 4..,, FAR60 COIPBULTANTS,TN'C. 11440 Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214352-4811 Report of Reinforcing Steel Observation Tested For: Holt Lansford Commercial Project Name: Coppell Trade Center Building D Coppell, Texas Locations and Items Observation: Fire lane/drive (Northeast portion) Date of Service: 12/07/06 FCI Project No.: M06-1165 Items Ins ected Conforming Items Ins ected Conforming Items Ins ected Conforming Placing Drawings Bar Length and Column Ties Approved le$ Shape yes Properly Tied N/A and S aced Bar Size yes Proper Bar yes Stirrup Spacing N/A Placement and T e Bar Grade Yes Properly Tied Yes Lapped Splices Yes Bar Clean Yes Dowel Bars in yes Welded Splices N/A Place Form Clean N/A Pr-0per Bar yeS Mechanical N/A Su orts Slices Number of Bars Yes Proper Cover Yes N/A: Indicates not applicable Remarks: Discrepancies observed were corrected prior to and during the placement of concrete. Technician: Dustin Allen Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppell -Larry Davis Respectfully Submitted, Fargo Consultants, Inc. Checked by: LIMITATIONS: This report presents test resulu (at particular locations noted) based on data obtained from specific samples selected for testing, Fargo Consultants, inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, ]nc. Ceotechnical Engineering • Construction Materials Testing • Environmental Services unwv. dallasfargo. com