Coppell Trade 2-LR061207~ 4..,,
FAR60 COIPBULTANTS,TN'C.
11440 Reeder Rd. • Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214352-4811
Report of
Reinforcing Steel Observation
Tested For: Holt Lansford Commercial
Project Name: Coppell Trade Center Building D
Coppell, Texas
Locations and Items Observation: Fire lane/drive (Northeast portion)
Date of Service: 12/07/06
FCI Project No.: M06-1165
Items
Ins ected Conforming Items
Ins ected Conforming Items
Ins ected Conforming
Placing Drawings
Bar Length and Column Ties
Approved le$
Shape yes Properly Tied N/A
and S aced
Bar Size yes Proper Bar yes Stirrup Spacing N/A
Placement and T e
Bar Grade Yes Properly Tied Yes Lapped Splices Yes
Bar Clean Yes Dowel Bars in yes Welded Splices N/A
Place
Form Clean N/A Pr-0per Bar yeS Mechanical N/A
Su orts Slices
Number of Bars Yes Proper Cover Yes
N/A: Indicates not applicable
Remarks: Discrepancies observed were corrected prior to and during the placement of concrete.
Technician: Dustin Allen
Distribution: Holt Lansford Commercial -Ken Newman
Mcfadden & Miller -Jon Jacobson
City of Coppell -Larry Davis
Respectfully Submitted,
Fargo Consultants, Inc.
Checked by:
LIMITATIONS: This report presents test resulu (at particular locations noted) based on data obtained from specific samples selected for testing, Fargo Consultants, inc. assumes no
responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed
and may not be reproduced except in full without the written approval of Fargo Consultants, ]nc.
Ceotechnical Engineering • Construction Materials Testing • Environmental Services
unwv. dallasfargo. com