Loading...
Service Star-LR070125 CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0040 Service Date: November 29, 2006 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1 01 0 o Gallons o Gallons Report Date: January 25, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: November 29, 2006 Time: 11 :00 AM Sampled by: Jesus Rojas Weather Conditions: Cloudy, windy Accumulative Yards: 3/3 Batch Size (cy): 3.00 Placement Method: Direct Discharge Sample Locations: Refer to placement location Placement Location: Manhole @ Sta. 0+00 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Material Information Specified Strength: 4200 psi @ 28 Days Batch Time: 10:21 AM Plant: 1 Supplier: Redi-Mix Concrete Truck No: 204 Mix I.D. No.: 342L 1504 Water Added Onsite Before Test: Water Added Onsite After Test: Ticket No: 181233 Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 2.50 3.3 78 80 146.8 Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C 1064 ASTM C138 Laboratorv Test Data Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 139,180 4,920 28 176,660 6,250 28 181,960 6,440 Average (28 Days) 6,350 4 6.00 28.27 01/24/2007 56 198,600 7,020 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 1 1 1 Specimen ID 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Date Tested 12/06/2006 12/27/2006 12/27/2006 Terracon Rep: Jesus Rojas Report Distribution: (1) ServiceSlar Design Group LLC (1) City or Coppell TX (1) City of Coppell TX (1) ICI Construction Inc (1) ICI Construction 'nc (1) Pate Engineers (1) ServiceSlar Design Group LLC (1) Ratliff Group LLC Reviewed by: Lyndon J. C Principal E The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 D1-PDR/F!01.FuI1Jre Key