Loading...
Service Star-LR070116 CONCRETE COMPRESSIVE STRENGTH TEST , v Report Number: 94061329.0054 Service Date: December 18, 2006 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: January 16, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Sample Information Date Cast: December 18, 2006 Time: 10:35 AM Sampled by: Eric G. Jernigan Weather Conditions: Partly cloudy, mild Accumulative Yards: 20/60 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: S Half of Fire Lane, (See attached sketch.) Placement Location: Pavement, Fire Lane & Center Drive/Approach to Bank Drive- Thru, (See attached sketch.) Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 9:49 AM Plant: 01 Supplier: Nelson Bros. Ready Mix Truck No: 103 Ticket No: 172382 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature, of: Plastic Unit Weight, pcf: Result 4.75 2.8 77 75 145.6 * Specification 3-5 4.5-7.5 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 * = Field Test Results do not meet project specifications. Laboratorv Test Data Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 95,590 3,380 28 126,360 4,470 28 127,270 4,500 Average (28 Days) 4,490 1 4 02/12/2007 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Field Results Reported To: Israel w/Westex Set No. Specimen ID 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Date Tested 12/25/2006 01/15/2007 01/15/2007 Terracon Rep: Eric G. Jernigan Report Distribution: (1) ServiceStar Design Group LLC (1) City of Coppell TX (1) City of Coppell TX (1) ICI Construction Inc (1) ICI Construction Inc (1) Pate Engineers (1) ServiceStar Design Group LLC (1) RaUiff Group LLC Reviewed by: Lyndon J. Principal The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the u f the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01-PDRIR01-FiAurl Key vi S -f-N e ( "<?tzoPoMU l 8c..t:>G. ..;- - , I f~~ I \ (1) - JAMp~ fA fUN l~7 - bp-~D. 9t"Jb"p 1D~Ay 0-0 P o]ldJ 13 L)~ . F;p.F~#';::- f,/ot?/32.9. ()()R 12-1$~ of,. Terracon Report No.94061329.0054, Dated 12/18/2006 Multi-Facility Concept