Loading...
Service Star-LR070115 CONCRETE COMPRESSIVE STRENGTH TEST . Report Number: 94061329.0051 Service Date: December 15, 2006 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: January 15, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Samole Information Date Cast: December 15,2006 Time: 8:20 AM Sampled by: Polikarp J. Labecki Weather Conditions: Cloudy Accumulative Yards: 30/130 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: 30' S & 5' E of NW corner of pavement - Sample #1 on Sketch Placement Location: Pavement, Fire Lane & Parking Lot, E of Firestone Bldg., (See attached sketch.) Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 7:27 AM Plant: 01 Supplier: Nelson Bros. Concrete Truck No: 219 Ticket No: 172311 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: -Gallons Water Added Onsite After Test: - Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 5.00 2.0 67 57 148.3 * Specification 3-5 4.5-7.5 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Laboratory Test Data * = Field Test Results do not meet project specifications. Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 118,660 4,200 28 157,100 5,560 28 152,310 5,390 Average (28 Days) 5,480 4 02/09/2007 56 Services _ Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 1 1 1 Specimen ID 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Date Tested 12/22/2006 01/12/2007 01/12/2007 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 2 01-PDRIR01-Fulur8 Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061329.0051 Service Date: December 15, 2006 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: January 15, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Samole Information Date Cast: December 15, 2006 Time: 10:10 AM Sampled by: Polikarp J. Labecki Weather Conditions: Cloudy Accumulative Yards: 110/130 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: Sample #2 on Sketch. Placement Location: Pavement, Fire Lane & Parking Lot, E of Firestone Bldg., (See attached sketch.) Material Information Specified Strength: 3500 psi @ 28 Days Batch Time: 9:18 AM Plant: 01 Supplier: Nelson Bros. Concrete Truck No: 223 Ticket No: 172326 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: - Gallons Water Added Onsite After Test: - Galtons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, of: Ambient Temperature,oF: Plastic Unit Weight, pcf: Result 5.00 5.5 67 59 142.6 Specification 3-5 4.5-7.5 Test Method ASTM C143 ASTM C231 ASTM C 1064 ASTM C 1064 ASTM C138 Laboratorv Test Data Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 111,130 3,930 28 125,980 4,460 28 128,990 4,560 Average (28 Days) 4,510 2 4 02/09/2007 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Set No. 2 2 2 Specimen ID 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Date Tested 12/22/2006 01/12/2007 01/12/2007 Terracon Rep: Polikarp J. Labecki Report Distribution: (1) ServiceStar Design Group LLC (1) City or Coppell TX (1) City or Coppell TX (1) ICI Construction Inc (1) ICI Construction Inc (1) Pate Engineers (1) ServiceStar Design Group LLC (1) Ratlifr Group LLC Reviewed by: Lyndon J. C x, P.E. Princip I E gineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 01-PDRtRQ1-Fulure Key 11\ rt~.~ ~I ...Frt - SIt~~f;,71orl e:Jt..l PflY\ tJ G,... It ~ E A =Wi ---.--- ".._~. //-/- Terracon Repo'rt No.94061329.0051, Dated 12/15/2006 . Multi-Facility Concept