Service Star-LR070215
FIELD DENSITY TESTING
Report Number: 940613290077
Service Date: February 7,2007
lrerracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client:
ServiceStar Design Group LLC
Attn: Frank Malek
5670 Greenwood Plaza Blvd, Suite 300
Greenwood Village CO 80111
Report Date:
Project:
February 15, 2007
Multi-Facility Concept
(Firestone Store)
SWC Hwy. 121 & MacArthur Blvd.
Coppell, TX
94061329
Project No.:
Material
No.
Description and Classification
Dark brown clay
Lab Test Data
Optimum Max. Lab
Water Dry Unit
Content Weight
(%) (pcf)
20.6 98.6
Proiect Requirements
Materia/Information
Laboratory
Test Method
Water
Content
(%)
-1/+3
Minimum Dry
Unit Weight
(% compaction)
1 613290002 ASTM D 698
Field Test Data
Test
No.
95
Test Location
Probe Water Dry Unit Dry Unit
Lift! Mat. Depth Content Weight Weight
Elev. No. (inches) (%) (pcf) (% compaction)
6' BFG 1 6 20.0 97.2 99
6' BFG 1 6 22.5 95.6 97
6' BFG 1 6 21.7 96.5 98
8" Storm Sewer Trench Backfill
133 2' S & 3' E of NE cor. of Bldg. #2
134 100' S & 5' E of NE cor. of Bldg. #2
135 5' S & 30' E of SE cor. of Bldg. #2
Datum: BFG = Below Final Grade
Comments:
Test results on this report meet project specification.
Services _ Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method: ASTM 0-2922, ASTM D-3017
Terracon Rep: Christopher D. Harbour
Field Results Reported To: T.M. w/ICI
Report Distribution:
(1) ServiceStar Design Group LLC
(1) City of Coppell TX
(1) City or Coppell TX
(1) ICI Construction 'nc
(1) ICI Construction Inc
(1) Pate Engineers
(1) ServiceStar Design Group LLC
(1) Ratliff Group LLC
Reviewed by:
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusivel or the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1
07.POR/R07.Fulure Key