Loading...
Service Star-LR070213 . REPORT OF DRILLED BELLED PIER OBSERVATION 'Report Number: 94061329.0071 Service Date: February 6, 2007 lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Project No.: February 13,2007 Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX 94061329 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Report Date: Project: Services: Drilled belled pier observation. On this date, Terracon's representative arrived at the above referenced job site as scheduled for drilled belled pier observation. Drilling rig arrived on site at 9:00 AM. Terracon's representative observation that on this day, Trinity drilling made 3 attempts to complete an 18 inch diameter pier shaft with a 54 inch diameter bell at a depth of 10 feet from existing grade. Locations of the 3 attempts spanned the site. All 3 of the shafts encountered caving soils at a depth ranging form 7 to 9 feet below existing grade. At the pier @ A/1, ground water seepage was encountered at 8.2 feet making the shaft sensitive to sloughing conditions and impossible to maintain a dry bearing surface. Based on the conditions encountered in the excavation of the shafts, it was determined that a new method should be used in the completion of the piers. The holes were backfilled with cuttings and will be redrilled at a later date when a new plan is developed. See the attached sheet for recorded data. Terracon Rep: Daniel J. Drogos Report Distribution: 9 ~ (1) ServiceStar Design Group LLC (1) ICI Construction Inc ' (J I) (1) City of Cop pel IT X (1) Pate Engineers Reviewed by: ~_ (1) City or Coppell TX (1) ServiceStar Design Group LLC ~ (1) ICI Construction 'nc (1) Ratliff Group LLC Lyndon . Cox, P E Princi I Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 99-PDRIR99.Future Key Cg 0 0 D~ it 2 0; u~ CI) f~ rD~ u..~ ~"-o ,-g OJ '" ;; '-~ c OJ ~ OJ X . a.!Yt ~~ ~ U .<0 r-- ..-~~ 0 0 ~~~ 0 r-u 0\ [fJ 0 N r-- 01) M 0 ....... -...... 0 lr) i-< ....... \0 0 Q 4-< 0 -...... 0 -.::t N 0\ 0 Q ....... 0 CD I: CD " III Cl Z .~ 'u III 1:: 'c c.. 0 Gl en .l: c. ..... " Gl c:: 0 Gl Gl to- -; C >< i=-< en 0:: w - c.. c W ....J ....J W CO C W ...J ...J 0:: C LL o .- 0:: o a.. w 0:: ....... Q) p.. p.. o U -d ~ o:l i-< ;::j ..c t ~ u ro ~ o'd ....... ~N V ....... r.J) ro ...:::: 0... >-. ~ ::r:: U :5 ifJ +-' p.. (l) U ::: o U >-. .;:::: ...-< ....... u ro ~ I ....... .... '""5 ~ --. (l) i-< o .... ifJ (l) 0\ ::: N o M tJ....... (l) \0 i-< 0 r..L;-.::t '-' 0\ o Gl '0 a. o z ..... U Gl '0 ... c.. OJ) ::: ....... ...-< :-a Q :>-. .... .S '1:: i=-< L: ~ 'i: C N UJ <:') <( ~ l: o :;::; I1l U ;;:: :;::; l: Q) :!2 .... Q) i:i: co .,.... co .,.... co .,.... c: .... Q) - Q) E I1l C .... Q) i:i: '<t L() '<t L() '<t L() I: .... Q) - Q) E I1l o ai CO <:( z ~ o .,.... <:( z ~ o .,.... <:( z ~ o .,.... g c o :;::; I1l > Q) w ~Cl Cl os: l: l: .........; :;:; Q) III III -g'X 'X ....W W ~ g E .!!! J:: e >< s... ':: W.!!! .!!! Eo.. a.. e'O '0 ~.s J:: -c.a.-c.- A. .!!! os: Q) os: -.... ~C ~ C_Q) Q) C'Il'Ciij'C g:E~l:~ o:::EClii:Cl .... .!!! a.. - o c. o I- C'? N .,.... <:') o .,.... ~ o .,.... <:( z <:( z <( z <:( z <:( z <( z g Q) - Q) .... u c o U - o c. o l- E o .... - J:: - C. Q) C ~ o ~ o - ell ::;: ~ 'C .... o - Q) ~ E o - - o CO - o I: o ;:: :c c o U en ell >- lJl ell >- lJl Q) >- 0' l: .... o III Q) .b Q) U I: I1l .... ~ o l- I: J:: - ~ .c E :J a.. <:( z <( z <( z '2 .... Q) - Q) E I1l C Cl l: III I1l U <:( z <( z ~ z os: J:: - C. Q) C "0 Q) III C'Il U <:( z <:( z ~ z ~ lli ~ ~ I1l CO iij u 1:: Q) > - o ... Q) .c E :J Z ~ z <:( z <( z E Q) .!:::! en .... I1l co Cl I: 'u .... o - c .; 0::: <( z <:( z <( z ~ :E. ~ I1l co iii " 1:: Q) > - o J:: - Cl I: Q) ...J :2: <:( L() ? Q) '0 z Q) Q) (j) .,.... .,.... :2: <:( <:') c:'! o .,.... Q) '0 z Q) Q) (j) :2: <( N <:') m <J) "0 z Q) Q) (j) 'C Q) .... ~ c. E o U III I1l ;:: Cl I: "C Q) U I1l a.. III I1l ;:: Q) - Q) .... U l: o U Q) E i= .;: C Q) E i= Specification 3-5 4.5-7.5 * = Field Test Results do not meet project specifications. Age at Maximum Compressive Test Load Strength (days) (Ibs) (psi) 7 95,590 3,380 28 126,360 4,470 28 127,270 4,500 Average (28 Days) 4,490 1 4 6.00 28.27 02/12/2007 56 136,880 4,840 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Field Results Reported To: Israel wlWestex CONCRETECOMPRESSWESTRENGTHTEST ~Report Number: 94061329.0054 Service Date: December 18, 2006 Client: ServiceStar Design Group LLC Attn: Frank Malek 5670 Greenwood Plaza Blvd, Suite 300 Greenwood Village CO 80111 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 9:49 AM Plant: 01 Supplier: Nelson Bros. Ready Mix Truck No: 103 Ticket No: 172382 Mix I.D. No.: PD36AEA Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, OF: Ambient Temperature, OF: Plastic Unit Weight, pcf: Result 4.75 2.8 77 75 145.6 * Laboratorv Test Data Set No. 1 1 1 Specimen ID 1 2 3 Diameter Area (inches) (sq. inches) 6.00 28.27 6.00 28.27 6.00 28.27 Terracon Rep: Eric G. Jernigan lrerracan 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Report Date: February 13, 2007 Project: Multi-Facility Concept (Firestone Store) SWC Hwy. 121 & MacArthur Blvd. Coppell, TX Project No.: 94061329 Samole Information Date Cast: December 18, 2006 Time: 10:35 AM Sampled by: Eric G. Jernigan Weather Conditions: Partly cloudy, mild Accumulative Yards: 20/60 Batch Size (cy): 10.00 Placement Method: Direct Discharge Sample Locations: S Half of Fire Lane, (See attached sketch.) Placement Location: Pavement, Fire Lane & Center Drive/Approach to Bank Drive-Thru, (See attached sketch.) Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Date Tested 12/25/2006 01/15/2007 01/15/2007 Report Distribution: (1) ServiceStar Design Group LLC (1) ICI Construction Inc (1) City of Coppell TX (1) Pate Engineers Reviewed by: (1) City of Coppell TX (1) ServiceStar Design Group LLC L dE C P E (1) ICI Construction Inc (1) Ratliff Group LLC yn 0 . OX, . . Prin p Engineer fhe tests were performed in general accordance with applicable ASTM, AASHTO. or DOT test methods. This report is exclusively the use of the client ndicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable :0 the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical naterials. Page 1 of 1 01.PDRiR01-Fulurll Key vi g -f-N --- r:; (~.Pojy,LJ l 8c-t>~. , -=---=- I !~~ I r ~PD~ 13 L)S . 0- SJAMftF (jJ tCfIl 1~7 - f)(Zr;~ 9t.vcP 1D ~}.'/ fr"PEJh:>~~ c;t/o{;,/32.9. ()()A 12-/ $- Df, Terracon Report No.94061329.0054, Dated 12/18/2006 Multi-Facility Concept