Loading...
Stonemeade-LR 930125MAXIM ENGINEERS, INC. Engineering and Environmental Consultants 2342 Fabens • P.O. Box 59902 • Dallas, TX 75229 (214) 247 -7575 a FAX (214) 484 -5804 IN -PLACE DENSITY OF SOIL I Report Date 01/25/93 Sample Date 01/22/93 Client Centex Real Estate Project Number 0392002035 Project Name Stonemeade Estates - Utilities - Coppell, Texas 112.9 14.7 Density Test Method ASTM D2922 and D3017 Method of Compaction ASTM D698 Project Density Req'd 90 Project Moisture Req'd opt +5 Material Material Proctor Results Location Number Description Maximum Dry Density (pcf) Optimum Moisture % 1 Dark Brown and Brown Sandy Clay with roots 112.9 14.7 2 Tan and Yellow Brown Sand 112.4 10.5 "I rhrlr Rrnwn elav with rnnts and calcareous nodules 101.6 19.9 Test Results Test Material Lift Location Dry Density Moisture % of Maximum Number Number (lbs /cu. ft.) Content ( %) Dry Density 6 1 Final 8" Sanitary Sewer, Line D, Station 2 +00 107.4 18.1 95.1 7 1 Final 8" Sanitary Sewer, Line D, Station 2 +50 106.7 18.6 94.5 8 1 Final 8" Sanitary Sewer, Line D, Station 3 +00 106.7 17.1 94.5 9 1 Final 8" Sanitary Sewer, Line D, Station 5 +00 108.3 17.2 95.9 10 1 Final 8" Sanitary Sewer, Line D, Station 5 +25 107.3 18.2 95.0 11 2 Final 8" Sanitary Sewer, Line F, Station 0 +40 97.8 23.0* 87.0 ** 12 3 Final 8" Sanitary Sewer, Line D, Station 5 +50 101.1 20.5 99.5 13 1 Final 8" Sanitary Sewer, Line D, Station 6 +00 106.4 15.8 94.2 14 1 Final 8" Sanitary Sewer, Line D, Station 5 +50 103.4 16.9 91.5 15 2 Final Retest of Station 0 +40, Line F 96.3 18.6* 94.7 16 2 Final 8" Sanitary Sewer, Line F, Station 1 +00 103.1 19.2* 101.4 * Does not meet project specifications for moisture content percent. ** Does not meet project specifications for percent of maximum dry density. Technician: T. Pickens /vb Centex Real Estate Corporation - Derek Earle, P.E. C. W. Young City of Coppell - Larry Davis City of Coppell - Garreth D. Campbell, Sr. This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report applies only to the sample tested does not necessarily represent identical or similar samples. MAXIM ENGDCMtS, DW_ 25V U A! -)