Huntington-LR 930521jIIIAXIM ENGINEERS, INC.
Engineering and Environmental Consultants
2342 Fabens • P.O. Box 59902 • Dallas, TX 75229
(214) 247-7575 ~ FAX (214) 484-5804
CONCRETE CYLINDER TEST REPORT ~
Report Date 05/21/93 Sample Date 04/20/93
T~ Centex Real Estate
ProjeM # 0393000704
Project Huntington Ridge -Utilities -Coppell, Texas
contractor Guzman Construction
Location of Placement Manhole at station 6+50
Standard 6" X 12"
Area 28.27 Square inches
~/(e •TL+n T /~ j ~`
I~ll"~L Sonrce, Design SSD Balch OTHER DATA
lYi[ ,1 ~ Description Wts. (Lbs./Cu.Yd.)
Mix No.: N/A Concrete Supplier: Redl Mlx
Cement. Ticket No.: 03853 Truck No.: N/A
Fly Ash: Time Batched: 12:56 pm Sampled: 1:45 pm
Coarse Aggregate: Temperature (°F) Ambient: N/A Concrete: N/A
Fine Aggregate: Weather Conditions: Clear and Wlndy
Water Added: 3 gallons Batched: Entrained Air Content (46): 3.2%
Admixtures: (ASTM C-231)
Specimen Number ASe Date Tested Slump In. Total Load Lbs. Comprehensive
Strength P.S.I. Type of
Fracture Strength Required
P.S.1./days
(Days)
HRU 13 7 04/27/93 1/2 141000 4987 ~ 4000/28
14 7 04/27/93 138900 4913
15 28 05/17/93 163200 5773 a
16 28 05/17/93 160600 5681
Curing ASTM C-31 Test Method Cylinders Made By Cylinders Tested By
Slump ASTM C-143 ASTM C-39 A. Campbell I. Lopez
Remarks and/or Distribution
/cey
Centex Real Estate Corporation -Derek Earle, P. E.
City of Coppell -Larry Davis
City of Coppell - Garreth D. Campbell, Sr.
This report is for the sole use of the client addressed. The use of our mmpany name must receive our prior written mnsen[. This report applies only ro the sample tested. and
does no[ necessarily representiden[ical or similar samples. 03163
rrtA~m~t rrcu~tt~~xs, uac