Loading...
Huntington-LR 930314MAXIM ENGINEERS, INC. 2342 Fabens • P.O. Box 59902 ~ Dallas, TX 75229 Engineering and Envlronmenkil Consultants (214) 247-7575 • FAX (214) 4845804 IN-PLACE DENSITY OF SOIL Report Date 03/14/93 Sample Date 03/10/93 Client Centex Real Estate Project Number 0392002034 Project Name Huntington Ridge -Coppell, Texas Density Test Method ASTM D2922 and D3017 Method of Compaction ASTM D698 Project Density Req'd 95 t0 102 Project Moisture Req'd Opt +5 Mcst~re~Dens Relations tY Material Proctor Results Number Description Maximum Dry Density (pcf) Optimum Moisture 1 • Yellow brown clay with calcareous nodules 108.8 14.9 2 Gray shaley clay with yellow seams 89.2 28.2 Test Results Test Material Lift Location Dry Density Moisture % of Maximum Number Number (Ibs/cu. ft.) Content (°h} Dry Density 101 1 1st House pad, block A, lot 15 104.2 16.0 96.0 102 2 1st House pad, block A, lot 13 86.7 29.2 97.2 All densities meet project specifications unless otherwise noted. Technician: T. Pickens /cey Centex Real Estate Corporation -Derek Earle, P.E. Rodman Excavation -Rod Vilhoyer City of Coppell -Larry Davis / City of Coppell - Garreth D. Campbell, Sr. This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report applies only to the sample tested, and does no[ necessarily represent identical or similar samples. 1~ `~H~A0a11 MAXIM ENGINEERS, INC. Engineering and Environmental Consultants 2342 Fabens • P.O. Box 59902 ~ Dallas, TX 75229 (214) 247-7575 ~ FAX (214) 484 4 IN-PLACE DENSITY OF SOIL Report Date 03/14/93 Client Centex Real Estate Project Name Huntington Ridge -Coppell, Texas Density Test Method ASTM D2922 and D3017 Project Density Req'd 95 t0 102 Sample Date 03/11/93 Project Number 0392002034 Method of Compaction ASTM D698 Project Moisture Req'd Opt +5 wlosttireJDensity Relations Material Proctor Results Number Description Maximum Dry Density (pcf) Opfimum Moisture 1 ~ Tan and brown clay with tan calcareous clay 93.0 25.3 Test Results Test Material lift Location Dry Density Moisture `% of Maximum Number Number (Ibs/cu. ft.) Content (%) Dry Density 103 1 2nd House pad, block A, lot 15 90.5 26.1 97.3 All densities meet project spec cations unless otherwise noted. Technician: T. Pickens /br Centex Real Estate Corporation -Derek Earle, P.E. Rodman Excavation -Rod Vilhouer City of Coppell -Larry Davies City of Coppell - Garreth D. Campbell, Sr. This report is for the sole use of the client addressed. The use of our company name must receive our prior written consent. This report applies only to the sample tested, and does not necessarily represent identical or similar samples. ~~ _ HR012 YAx9s HiC9~, ING ~/~"`~4t RK~