Vistas of C P2-LR 980404FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: April 4, 1998 PROJECT: Vistas of Coppell, Phase 1B &2C Coppell, Texas Project No.: 0771 -2221 SAMPLE DATE: March 4, 1998 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Glenn Thurman, Inc. CONCRETE SUPPLIER: On Site 60 PLANTITRUCK: 61 MIX ID NUMBER: 10:00 am AIR ( %) ( ASTM C -231) 6 10:15 am WATER ADDED (gal): Cloudy, windy SLUMP (inches) (ASTM c -143) 2.5 Paving - machine: Alley B, station 5 +50 CONCRETE CYLINDER' COMPRESSIVE'STRENGTH TESTS Standard 6" x 12" 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) REQUIRED COMPRESSIVE STRENGTH (psi) VCC 81 7 3/11/98 93000 3290 3600/28 days VCC 82 28 4/1/98 127000 4493 VCC 83 28 4/1/98 130000 4599 VCC 84 Hold Specifications: Making & ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 Curing: REMARKS: Unit weight 142 lbs. /cu. ft. Technician: William Freeze FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: - -- SMH /rm Distribution: Centex Homes - Robert Poole Glenn Thurman City of Coppell - Garreth Campbell FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: April 4, 1998 PROJECT: Vistas of Coppell, Phase 1B &2C Coppell, Texas Project No.: 0771 -2221 SAMPLE MATE: March 4, 1998 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Glenn Thurman, Inc. CONCRETE SUPPLIER: On Site 58 PLANT/TRUCK: 61 MIX ID NUMBER: 7:40 am AIR ( %) ( ASTM C -231) 5 8:00 am WATER ADDED (gal): cloudy, windy SLUMP (inches) (ASTM C -143) 2.5 Paving - machine: Alley A, station 2 +00 CONCRETE' CYLINDER! COMPRESSIVE.STRENGTH TESTS Standard V x '12 ",;28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (Psi) REQUIRED COMPRESSIVE STRENGTH (psi) VCC 77 7 3/11/98 90000 3184 3600/28 days VCC 78 28 4/11/98 133000 4705 VCC 79 28 4/11/98 135000 4776 VCC 80 Hold Specifications: Making & ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 Curing: REMARKS: Unit weight 145 lbs. /cu. ft Technician: William Freeze FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: SMH /rm Distribution: Centex Homes - Robert Poole Glenn Thurman City of Coppell - Garreth Campbell FUGRO SOUTH, INC. ��aRO i 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date April 4, 1998 PROJECT Vistas of Coppell, Phase 1B &2C Coppell, Texas Project No .: 0771 -2221 SAMPLE DATE: March 4, 1998 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Glenn Thurman, Inc. 66 64 1:30 pm 2:00 pm cloudy, windy Paving, hand paved CONCRETE SUPPLIER: On Site PLANT/TRUCK: MIX ID NUMBER: AIR ( %) (ASTM C -231) 5 WATER ADDED (gal): SLUMP (inches) (ASTM c -143) 3 Waterview Ct., Station 1 +00, center of cul -de -sac CONCRETE CYLINDER'' COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) REQUIRED COMPRESSIVE STRENGTH (psi) VCC 85 7 3/11/98 118000 4175 3600/28 days VCC 86 28 4/1/98 153000 5413 VCC 87 28 4/1/98 156000 5519 VCC 88 Hold Specifications: Making & ASTM C -31 Testing Methods: ASTM C -143, ASTM C-39 Curing: REMARKS: Unit weight 147 lbs. /cu. ft. Technician: William Freeze Checked By: �f = _ SMH /rm Distribution: Centex Homes - Robert Poole Glenn Thurman City of Coppell - Garreth Campbell