Loading...
Vistas of C P2-LR 980403FUGRO SOUTH, INC. L E 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: April 3, 1998 PROJECT: Vistas of Coppell, Phase 113 &2C Coppell, Texas Project NO.: 0771 -2221 SAMPLE DATE: March 3, 1998 CONTRACTOR: Glenn Thurman, Inc. TICKET NO.: CONCRETE SUPPLIER: On Site AMBIENT TEMP. (°F): 62 PLANT/TRUCK: On Site /60 C.Y. CONCRETE TEMP. (°F): 66 MIX ID NUMBER: TIME BATCHED: 7:45 AIR ( %) (ASTM C -231) 5.5 TIME SAMPLED: 7:50 WATER ADDED (gal): 0 WEATHER CONDITION: Overcast SLUMP (inches) (ASTM C -143) 53/4 LOCATION OF PLACEMENT: Rock Crest Court, sampled at station 1 +00 Technician: Michael Flute FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By SMH /rm Distribution: Centex Homes - Robert Poole Glenn Thurman Inc. City of Coppell - Garreth Campbell REMARKS: Unit Weight: 134.8 Ibs /cu. ft. FUGRO SOUTH, INC. �GRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes PROJECT Vistas of Coppell, Phase 1B & 2C Coppell, Texas Report Date April 3, 1998 Project No.: 0771 -2221 SAMPLE DATE:. March 5, 1998 1 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Glenn Thurman, Inc. CONCRETE 'CYLINDER COMPRESSIVE STRENGTH TESTS Standard V x 12" 28.27 square inches CONCRETE SUPPLIER: On Site 68 PLANT/TRUCK: On Site /237 72 MIX ID NUMBER: 7 1:37 AIR ( %) (ASTM C -231) 5.5 1:40 WATER ADDED (gal): 0 Sunny SLUMP (inches) (ASTM C -143) 53/4 Pavement on grade, Alley A, sampled at eyebrow of corner VCC 95 CONCRETE 'CYLINDER COMPRESSIVE STRENGTH TESTS Standard V x 12" 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) REQUIRED COMPRESSIVE STRENGTH (psi) VCC 93 7 03/12/98 130000 4599 3000/28 days VCC 94 28 04/02/98 135000 4775 VCC 95 28 04/02/98 139000 4916 VCC 96 Hold Specifications: Making & ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 Curing: REMARKS: Technician: Mike Flute FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: SMH /rm Distribution: Centex Homes - Robert Poole Glenn Thurman Inc. City of Coppell - Garreth Campbell