Loading...
Vistas of C P2-LR 980326FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: March 26, 1998 PROJECT: Vistas of Coppell, Phase 113 &2C Coppell, Texas Project No.: 0771 -2221 SAMPLE DATE: February 24, 1998 CONTRACTOR: Glenn Thurman AGE (days) TICKET NO.: TOTAL LOAD (pounds) CONCRETE SUPPLIER: On Site AMBIENT TEMP. (°F): 50 PLANT/TRUCK: On Site CONCRETE TEMP. (°F): 58 MIX ID NUMBER: 28 TIME BATCHED: 8:25 AIR ( %) (ASTM C -231) TIME SAMPLED: 8:35 WATER ADDED (gal): 0 WEATHER CONDITION: Cloudy SLUMP (inches) (ASTM c -143) 3 LOCATION OF PLACEMENT: Paving: 200 feet east from Bella Vista on Clairmont Court CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard V x 1€2", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) REQUIRED COMPRESSIVE STRENGTH (psi) VCC 5 7 03/03/98 87000 3078 3000/28 days VCC 6 28 03/24/98 123000 4351 VCC 7 28 03/24/98 120000 4245 VCC 8 Hold Specifications: Making & ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 Curing: REMARKS: Technician: Scott Rogers FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: SMH /rm Distribution: Centex Homes - Robert Poole Glenn Thurman Inc. City of Coppell - Garreth Campbell FUGRO SOUTH, INC. GRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 4848301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: March 26, 1998 PROJECT: Vistas of Coppell, Phase 1B &2C Coppell, Texas Project No.: 0771 -2221 SAMPLE DATE: February '24, 1998 CONTRACTOR: Glenn Thurman TICKET NO.: CONCRETE SUPPLIER: On Site AMBIENT TEMP. (°F): 67 PLANT/TRUCK: On Site CONCRETE TEMP. (°F): 68 MIX ID NUMBER: TIME BATCHED: 11:30 AIR ( %) ( ASTM C -231) TIME SAMPLED: 11:40 WATER ADDED (gal): 0 WEATHER CONDITION: Clear SLUMP (inches) (ASTM C -143) 2.5 LOCATION OF PLACEMENT: Paving: 10 Feet east from western most point of circle at Willow Ridge Court CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard B" x 12 ", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) REQUIRED COMPRESSIVE STRENGTH (psi) VCC 9 7 03/03/98 95000 3361 3000/28 days VCC 10 28 03/24/98 120000 4245 VCC 11 28 03/24/98 117000 4139 VCC 12 Hold Specifications: Making & ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 Curing: REMARKS: Technician: Scott Rogers FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: ---- SMH /rm Distribution: Centex Homes - Robert Poole Glenn Thurman Inc. City of Coppell - Garreth Campbell FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: March 26, 1998 PROJECT: Vistas of Coppell, Phase 1B &2C Coppell, Texas Project No.: 0771 -2221 SAMPLE DATE: 'February ! 24, 1998 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Glenn Thurman CONCRETE SUPPLIER: On Site 71 PLANT/TRUCK: 78 MIX ID NUMBER: AIR ( %) ( ASTM C -231) 3:30 pm WATER ADDED (gal): 0 Clear SLUMP (inches) (ASTM C -143) 2.5 Paving: Forest Hill Drive, station 7 +50 CONCRETE ' CYLINDER 'COMPRESSIVE. STRENGTH TESTS Standard V' x 12", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (Psi) REQUIRED COMPRESSIVE STRENGTH (Psi) VCC 13 7 03/03/98 115000 4068 3000/28 days VCC 14 28 03/24/98 135000 4776 VCC 15 28 03/24/98 138000 4882 VCC 16 Hold L pecifications: Making & ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 Curing: REMARKS: Technician: Daniel Myers FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: ` -- —' SMH /rm Distribution: Centex Homes - Robert Poole Glenn Thurman Inc. City of Coppell - Garreth Campbell