Vistas of C P1-LR 970815FUGRO- McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: August 15, 1997 PROJECT: Vistas of Coppell, Phase 1A & 2B, Coppell, Texas Project No.: 0771 -2024 SAMPLE' DATE: July 15, 1997 CONTRACTOR: Glenn Thurman, Inc. AGE (days) TICKET NO.: N/A CONCRETE SUPPLIER: Glenn Thurman AMBIENT TEMP. (°F): 95 PLANT/TRUCK: On Site CONCRETE TEMP. (°F): 91 MIX ID NUMBER: N/A TIME BATCHED: 2:00 pm AIR ( %) (ASTM C -231) 5.2 TIME SAMPLED: 2:10 pm WATER ADDED (gal): 0 WEATHER CONDITION: Clear SLUMP (inches) (ASTM c -143) 2 LOCATION OF PLACEMENT: Paving: Jogging and bicycle trail, station 3 +25 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 11 , 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (Psi) REQUIRED COMPRESSIVE STRENGTH (Psi) VOC 144 7 07/22/97 105500 3731 3000/28 days VOC 145 28 08/12/97 127000 4492 VOC 146 28 08/12/97 130000 4598 VOC 147 Hold Specifications: Making & Curing: ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 REMARKS: Technician: Michael Overstreet FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: SMH /mv Distribution: Centex Homes - Derek Earle Glenn Thurman, Inc. City of Coppell - Garreth Campbell �GRO S FUGRO- McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date August 15 1997 PROJECT Vistas of Coppell, Phase 1A & 2B, Coppell, Texas Project No .: 0771 -2024 SAMPLE DATE: 'July 17, 1997 : CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Glenn Thurman N/A CONCRETE SUPPLIER: Contractor 85 PLANT /TRUCK: On site 86 MIX ID NUMBER: 5 7:50 am AIR ( %) (ASTM C -231) 5.2 8:00 am WATER ADDED (gal): 0 Clear SLUMP (inches) (ASTM C -143) 3 Paving, approach slab (south half) from MacArthur to Forest Hill Drive >CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (Psi) REQUIRED COMPRESSIVE STRENGTH (Psi) VOC 148 7 07/24/97 92000 3254 3000/28 days VOC 149 28 08/14/97 105000 3714 VOC 150 28 08/14/97 110000 3891 VOC 151 Hold Specifications: Making & Curing: ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 REMARKS: Technician: Mark Strittmatter FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: l SMH /mv Distribution: Centex Homes - Derek Earle Glenn Thurman, Inc. City of Coppell - Garreth Campbell --