Loading...
Vistas of C P1-LR 970730FUGRO- McCLELLAND (SOUTHWEST), INC. � GRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: July 30, 1997 PROJECT Vistas of Coppell, Phase 1A & 2B, Coppell, Texas Project No.: 0771 -2024 SAMPLE DATE: July 1,'1997 CONTRACTOR: Glenn Thurman, Inc. AGE (days) TICKET NO.: N/A CONCRETE SUPPLIER: GTI AMBIENT TEMP. (°F): 82 PLANT /TRUCK: On Site CONCRETE TEMP. (°F): 84 MIX ID NUMBER: N/A TIME BATCHED: 9:30 am AIR ( % ) (ASTM C -231) 5.2 TIME SAMPLED: 9:45 am WATER ADDED (gal): N/A WEATHER CONDITION: Sunny SLUMP (inches) (ASTM C -143) 2.75 LOCATION OF PLACEMENT: Paving: Alley B, sample taken at station 78 +12 near manhole CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (Psi) REQUIRED COMPRESSIVE STRENGTH (PSI) VOC 120 7 07/08/97 100000 3537 3500/28 days VOC 121 28 07/29/97 120000 4244 VOC 122 28 07/29/97 123000 4350 VOC 123 Hold Specifications: Making & Curing: ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 REMARKS: Unit Weight: 144.4 lbs. /cu. ft. Technician: Hector Salazar FUGRO- McCLELLAND (SOUTHWEST), INC. Checked B SMH /rm Distribution: Centex Homes - Derek Earle Glenn Thurman, Inc. City of Coppell - Garreth Campbell