Loading...
Vistas of C P1-LR 970718FUGRO- McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: July 18, 1997 PROJECT: Vistas of Coppell, Phase 1A & 2B, Coppell, Texas Project No.: 0771 -2024 SAMPLE DATE: July 10, 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Glenn Thurman, Inc. N/A CONCRETE SUPPLIER: N/A N/A PLANT /TRUCK: N/A N/A MIX ID NUMBER: N/A N/A AIR ( %) (ASTM C -231) N/A N/A WATER ADDED (gal): N/A N/A SLUMP (inches) (ASTM c -143) N/A Left turn lane Vista Ridge at Spur 553 VOC 126 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (Psi) REQUIRED COMPRESSIVE STRENGTH (psi) VOC 124 7 07/17/97 97000 3431 3000 days VOC 125 28 08/07/97 VOC 126 28 08/07/97 VOC 127 Hold S pecifications: Making & Curing: ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed to be correct. Technician: Daniel Myers FUGRO- McCLELLAND (SOUTHWEST), INC. Checked B SMH /rm Distribution: Centex Homes - Derek Earle Glenn Thurman, Inc. City of Coppell - Garreth Campbell FUGRO- McCLELLAND (SOUTHWEST), INC. — fuGRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date: July 18, 1997 PROJECT: Vistas of Coppell, Phase 1A & 2B, Coppell, Texas Project No.: 0771 -2024 I SAMPLE DATE: June 19, 1997 1 CONTRACTOR: Glenn Thurman, Inc. AGE (days) TICKET NO.: N/A CONCRETE SUPPLIER: Glenn Thurman AMBIENT TEMP. (°F): 82 PLANT/TRUCK: On Site CONCRETE TEMP. (°F): 86 MIX ID NUMBER: 5 TIME BATCHED: 7:50 am AIR ( %) (ASTM C -231) N/A TIME SAMPLED: 8:00 am WATER ADDED (gal): 0 WEATHER CONDITION: Clear SLUMP (inches) (ASTM C -143) 4.5 LOCATION OF PLACEMENT: Paving: Cresthaven Road cul -de -sac northwest quarter CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) REQUIRED COMPRESSIVE STRENGTH (psi) VOC 32 7 07/26/97 105000 3714 3000/28 days VOC 33 28 07/17/97 127000 4492 VOC 34 28 07/17/97 120000 4244 VOC 35 Hold Specifications: Making & Curing: ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 REMARKS: Technician: Mark Strittmatter FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By: - - SMH /rm Distribution: Centex Homes - Derek Earle Glenn Thurman, Inc. City of Coppell - Garreth Campbell FUGRO- McCLELLAND (SOUTHWEST), INC. 2rawn �� 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date July 18, 1997 PROJECT Vistas of Coppell, Phase 1A & 2B, Coppell, Texas Project No.: 0771 -2024 SAMPLE DATE: June 19, 1997 CONTRACTOR: Glenn Thurman, Inc. AGE (days) DATE TESTED TICKET NO.: N/A CONCRETE SUPPLIER: Glenn Thurman AMBIENT TEMP. (°F): 88 PLANT /TRUCK: On Site CONCRETE TEMP. (°F): 90 MIX ID NUMBER: 5 TIME BATCHED: 11:15 am AIR ( % ) (ASTM C -231) 5.2 TIME SAMPLED: 11:30 am WATER ADDED (gal): 0 WEATHER CONDITION: Clear SLUMP (inches) (ASTM C -143) 1 LOCATION OF PLACEMENT: Paving: Claremont Street, station 2 +25 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) REQUIRED COMPRESSIVE STRENGTH (psi) VOC 36 7 06/26/97 107000 3785 3000/28 days VOC 37 28 07/17/97 130000 4598 VOC 38 28 07/17/97 133000 4705 VOC 39 Hold Specifications: Makin 8 Curin : ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 REMARKS: Unit Weight: 149.2 lbs. /cu. ft. Technician: Mark Strittmatter FUGRO McCLELLAND (SOUTHWEST), INC. Checked By. —r- S M H /rm Distribution: Centex Homes - Derek Earle Glenn Thurman, Inc. City of Coppell - Garreth Campbell