Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Vistas of C P1-LR 970709
FUGRO- McCLELLAND (SOUTHWEST), INC. �IGRO ■ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date July 9, 1997 PROJECT Vistas of Coppell, Phase 1A & 2B, Coppell, Texas Project No .: 0771 -2024 F SAMPLE DATE: June 30, 1997 1 CONTRACTOR: Glenn Thurman, Inc. AGE (days) DATE TESTED TICKET NO.: N/A CONCRETE SUPPLIER: GTI AMBIENT TEMP. (°F): 76 PLANT /TRUCK: N/A CONCRETE TEMP. ff ): 85 MIX ID NUMBER: N/A TIME BATCHED: N/A AIR ( % ) (ASTM C -231) 5 TIME SAMPLED: N/A WATER ADDED (gal): N/A WEATHER CONDITION: Sunny SLUMP (inches) (ASTM C -143) 3 LOCATION OF PLACEMENT: Alley E and Westhaven Road CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) REQUIRED COMPRESSIVE STRENGTH (Psi) VOC 112 7 07/07/97 110000 3891 3000/28 days VOC 113 28 07/28/97 VOC 114 28 07/28/97 VOC 115 Hold Specifications: Making & Curing: ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 REMARKS: Technician: Daniel Myers FUGRO-McCLELLAND (SOUTHWEST), INC. Checked B SMH /rm Distribution: Centex Homes - Derek Earle Glenn Thurman, Inc. City of Coppell - Garreth Campbellx FUGRO-McCLELLAND (SOUTHWEST), INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Centex Homes Report Date July 9, 1997 PROJECT Vistas of Coppell, Phase 1A & 2B, Coppell, Texas Project No .: 0771 -2024 �GRO SAMPLE DATE: June 30, 1997 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Glenn Thurman, Inc. N/A 85 88 N/A 10:25 am Sunny Alley E, Rockcrest CONCRETE SUPPLIER: GTI PLANT /TRUCK: N/A MIX ID NUMBER: N/A AIR ( % ) (ASTM C -231) 5 WATER ADDED (gal): N/A SLUMP (inches) (ASTM c -143) 4 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (Psi) REQUIRED COMPRESSIVE STRENGTH (Psi) VOC 116 7 07/07/97 10000 3537 3000/28 days VOC 117 28 07/28/97 VOC 118 28 07/28/97 VOC 119 Hold Specifications: Making & Curing: ASTM C -31 Testing Methods: ASTM C -143, ASTM C -39 REMARKS: Technician: Daniel Myers FUGRO- McCLELLAND (SOUTHWEST), INC. Checked By7 SMH /rm Distribution: Centex Homes - Derek Earle Glenn Thurman, Inc. City of Coppell - Garreth Campbell