Hidden Creek-CS061120Monday, November 20, 2006
Gary L. Sieb, A.I.C.P.
Director, Department of Planning
255 Parkway Blvd.
City of Coppell, Texas 75019
(972) 304 -3678 T., (972) 304 7092 F.
Subject: "Hidden Creek Village" located in Coppell, Texas PD Application"
Dear Mr. Sieb:
es
RECEIVED
NOV 2 2 2006
PLANNING DEPARTMENT
I would like to submit the following information to help explain and highlight the planning concepts
as well as the arrival at the development conditions that have been thought out with regards to our
proposed planned development along Sandy Lake Road.
The first point of discussion is the reasoning for desiring a change to the current commercial zoning.
We naturally must adhere to and study "highest and best use" when examining any development
potential not only in the present, but out into the foreseeable future as well. Our request for
rezoning of this property to a medium density residential use is based on the following:
1. Currently existing weakness in the immediately surrounding commercial developments
including the closed down, boarded building at the North East corner of Sandy Lake
Macarthur, 41,475 SQFT of existing, vacant retail /commercial at the South East comer of
Sandy Lake Macarthur; Struggling, and mostly vacant garden office buildings
immediately across from site as well as multiple vacant tracts currently for sale along the
North East quadrant of Sandy Lake Macarthur Blvd.
2. Strong indication that future commercial, office, or retail projects at this location will have
weak demand due to the fact that a majoring of the surrounding areas are built out as well as
a majority of the property along Sandy Lake road lying within flood plain, unsuitable for
inhabitable development.
3. Taking advantage of the natural setting offered by the creek and utilizing this for the benefit
of residences versus a Sandy Lake fronting commercial use which most likely will back to
and ignore this natural beauty. It is important to note here that this is why we are asking for
a minimum lot depth of 92.4' and an average lot depth of 113.9'. This applies only to the
lots located in the center of the development due to the desire to create a buffer against
Sandy Lake Road with the 50' new street ROW. The 92.4' lot depth is the mathematical
result of the layout as proposed. The effect of requiring a 100' lot depth exclusive of the
constraints of the site would create houses backing up to Sandy Lake taking leaving siding
and rear elevations as the predominant view of the subdivision as is more often than not seen
in current subdivision planning.
Angled Lot Concept Description Advantages
Our lots set at a 30 degrees angle to the street with the garage doors facing away from the
sight of view from the street. This type of planning was originated in California.
pm
The Z -lot variation of the zero -lot-
line concept is intended to reduce the
negative visual effect of garage
doors, thus enhancing the street
appeal.
Rotates the home roughly 30 -45 degrees from its
traditional perpendicular relationship to the
roadway.
The benefits include:
Garage placement can be alternated to
maximize visual appeal.
Reduction in the length of the windowless
wall.
Increased perception (Areal. yard width.
Planned development conditions which [PD SF -7]
1. Reduce the lot depth minimum to 80.0', 92.4' mean, 113.9' average in order to allow for the
proposed subdivision layout which provides a 50' additional, fully landscaped, right of way
buffer along a majority of Sandy Lake Road.
2. Reduce the lot width to 40' front lot lines along the street as indicated (35' perpendicular to
the side lot lines) in an angled fashion 30 degrees to reduce the negative visual impact of
garage doors.
3. Front Yard setbacks shall be 15' minimum.
4. Side yard setbacks will be 5' -0"
5. Rear yard setback minimum to be 5' -0"
6. Minimum lot area is 2,800 SQ.FT.
7. Lot coverage: 45 percent [Due to desire to offer a master down plan option]
Planned development conditions which conform or exceed [PD SF -71
1. Minimum dwelling size will be 1,700 AC SQ FT vs. 1,200 AC SQFT allowed under SF -7.
2. Maximum height will be 35 feet nor more than two stories high.
3. Two enclosed off street parking spaces will be provided behind the front building line.
4. PD will meet the type of exterior construction allowed in SF -7. Lots 92, 93, 94, 95 which
back to Sandy Lake Road will be 100% masonry construction.
5. Maximum number of bedrooms will be three (3).
PHOTOS
#1. Views of creek along rear of property.
#2. Views of creek along rear of property.
#3. Struggling, vacant garden offices immediately across Sandy Lake
Road adjacent to property.
#4. Retail "strip center" at North East corner of Sandy Lake Road
Macarthur Blvd.
#5. Vacant, boarded up building at North East corner of Sandy Lake Road
Macarthur Blvd.
#6. 41,475 SQFT of existing, vacant commercial space at South East
comer of Sandy Lake Road Macarthur Blvd.
#7. Example of traditional subdivision design of houses backing up to
major streets back of houses becoming predominant view.
#8. Example of typical rear treatment of commercial and retail uses.
#9. Super Fiesta Bazaar along loop 12 in Dallas currently owned
operated by current owner of property, Peter Park.
#10. Super Fiesta Bazaar along loop 12 in Dallas currently owned
operated by current owner of property, Peter Park.