Loading...
St Ann Catholic-LR070305CONCRETE COMPRESSIVE STRENGTH TEST Irerracon Report Number: 94061334.0042 Service Date: February 19, 2007 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: March 05, 2007 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 94061334 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 1:44 PM Plant: 3 Supplier: Lattimore Materials Truck No: 1096 Ticket No: 3226448 Mix I.D. No.: 1261 Water Added Onsite Before Test: OGallons Water Added Onsite After Test: 0 Gallons Sample Information Date Cast: February 19, 2007 Time: 2 :35 PM Sampled by: Jeremy D. Lehnertz Weather Conditions: Windy, clear Accumulative Yards: 9/9 Placement Method: Direct Discharge Sample Locations: Refer to placement location Placement Location: Six (6) light pole bases @ parking, N side of addition; Six (6) bollards @ NW corner of building Field Test Data Test Result Specification Test Metho Slump, inches: 4.50 - ASTM C143 Air Content, %: 2.5 - ASTM C231 Concrete Temperature, oF: 75 - ASTM C1064 Ambient Temperature,oF: 80 ASTM C1064 Plastic Unit Weight, pcf: 148.8 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (s q. inches Tested (days (lbs) (psi) 1 1 6.00 28.27 02/26/2007 7 120,600 4,260 1 2 6.00 28.27 02/26/2007 7 119,299 4,220 Average (7 Days) 4,240 1 3 03/19/2007 28 1 4 03/19/2007 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Jeremy D. Lehnertz Report Distribution: (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX (1) Page Southerland Page . Bulent Ethem, P.G. Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01- PDR/ROI k,y