Coppell Trade 2-LR 070227i -
~~ ~~.
r ~„
FARGO CONBULTANTB, INC.
Report of
Reinforcing Steel Observation
Tested For: Holt Lunsford Commercial
Project Name: Coppell Trade Center Building D
Coppell, Texas
Locations Observation: Area paving northeast of building
11440 Reeder Rd. • Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214-352-4811
Date of Service: 2/27/07
FCI Project No.: M06-1165
Items Conforming Items Conforming Items Conforming
Ins ected Ins ected Ins ected
Placing Drawings Bar Length and Column Ties
Approved Yes Shape Yes Properly Tied N/A
and S aced
Bar Size Yes Proper Bar yeS Stirrup Spacing N/A
Placement and T e
Bar Grade Yes Properly Tied Yes Lapped Splices Yes
Bar Clean Yes Dowel Bars in yes Welded Splices N/A
Place
Form Clean Yes Proper Bar yeS Mechanical N/A
Su orts Slices
Number of Bars Yes Proper Cover Yes Void Box N/A
N/A: Indicates not applicable
Remarks: No discrepancies were observed
Technician: David Djikine
Distribution: Holt Lansford Commercial -Ken Newman
Mcfadden & Miller -Jon Jacobson
City of Coppell -Larry Davis
Respectfully Submitted,
Fargo Consultants, Inc.
Checked by:
LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, loc. assumes no
responsibility for variation in quality, performance, feature or conditions beyond its control This report is for the exclusive use of the person(s) to whom it is addressed
a~xl may not be reproduced except in full without We written approval of Fargo Consultants, [nc.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www. dallasfargo. com