Petterson Addn-CS070312 THE.CITY.OF March 12, 2007 Hamilton Duffy, PC Consulting Micha P. Duffy, P.E. 601 W. Harwood Rd. Hurst, IX 76054 RE: Petterson Addition Plan Review Comments Dear Mr. Duffy: The City of Coppell has received and reviewed the incomplete plans submitted for the Petterson Addition and has the following comments to offer: Replat 1. An easement document should be provided for the 8-inch waterline located approximately five feet off your west property line. In essence, this will require a minimum 10 foot utility easement that will abut the proposed 24 foot fire lane, utility and access easement. Please be advised that no landscaping of large trees, etc. will be allowed within that easement over the top of the waterline. Sheet C3.0 2. You will not be allowed to concentrate your water at the northwest corner of your property and then discharge it onto the adjacent property owner without adequate easements in place, grading in place and/or the installation of an underground system to take your water all the way to the proposed pond, approximately 500 feet to your northwest comer. Once you have adequately addressed your drainage issues, please provide two sets of revised plans to this office for a third review along with these marked-up plans. If you have any questions, please contact this office at your convenience. Sii:Y;f At- Kenneth M. Griffin, P.E. Director of Engineering/Public Works Office (972) 304-3686 Fax (972) 304-7041 Kgriffin@ci.coppell.tx.us 255 PARKWAY * P.O.BOX 947B * COPPELL TX 75019 * TEL 972/462 0022 * FAX 972/304 3673