Loading...
Coppell Cross 1P-LR 980616ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 /~~ Dallas, Texas 75229 (972) 620-8911 TESTED FOR MAVEX COPPELL CROSSING, LTD. LEWISVILLE, TEXAS PROJECT TEST DATA: COPPELL CROSSING COPPELL, TEXAS REPORT OF FIELD COMPACTION TESTS DATE 06/16/98 ouR REPORT No. 9 7 3 32 - 2 3 TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE MAXIMUM LAB DRY P~tTY IN PLACE Mom %RE IN PLACE DRY D~EFNSITY PERCENT COMPACTION COMMENT' ~ 06/16 FG-0.5 2 15.0 113.5 18.7 108 95 1-A 2 06/16 FG 3 20.5 101.5 23.0 100 99 1-A 3 06/16 FG-0.5 2 15.0 113.5 15.4 101 89 1-B ~ 4. 06/16 FG 2 15.0 113.5 24.9 96 85 1-BC 5 06/16 FG-0.5 2 15.0 113.5 18.9 107 94 1-B 6 06/16 FG 2 15.0 113.5 18.1 108 95 1-A I ~ 06/16 FG-0.5 2 15.0 113.5 13.6 105 92 1-BC TEST LOCATION: FIRE LINE UTILITY 1 APPROXIMATLEY 25' S AND 10' W OF THE 5E CORNER OF PAD 1 2 APPROXIMATLEY 25' S AND 15' W OF THE SE CORNER OF PAD 3 APPROXIMATLEY 25' S AND 20' E OF THE SE CORNER OF PAD ~4 APPROXIMATLEY 25' S AND 25' E OF THE SW CORNER OF PAD '5 ~ APPROXIMATLEY 20' W AND 50' N OF THE SW CORNER OF PAD 6 APPROXIMATLEY 20' W AND 40' N OF THE SW CORNER OF PAD 7 APPROXIMATLEY 20' W AND 90' N OF THE SW CORNER OF PAD /~ /I ~ ~ // /I ~. FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECI T S 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS esp Submitted 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DnFS N(~T C;nMPI V WITH SPFCIFIC:ATIC~NR a CEMENT TREATED D. RETEST ~ ESTI ,INC R FU I HERN~ ~ . ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 /~/ Dallas, Texas 75229 {972) 620-8911 MAVEX COPPELL CROSSING, LTD. TESTED FOR LEWISVILLE, TEXAS COPPELL CROSSING PROJECT COPPELL, TEXAS TEST DATA: REPORT OF FIELD COMPACTION TESTS DATE OUR REPORT NO. 06/16/98 97332-23A TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOI~URE MAXIMUM LA8 DRYPCFSITY IN PUKE MOISoURE IN PL4CE DRY~FSITY PERCENT COMPACTION COMMENT` 8 06/16 FG 2 15.0 113.5 13.6 105 92 1-BC 9 06/16 FG-0.5 3 20.5 101.5 22.4 101 99 1-A l0 06/16 FG 2 15.0 113.5 17.8 104 92 1-B 11 06/16 FG-0.5 3 20.5 101.5 2'1.7 100 99 1-A 12 06/16 FG 3 20.5 101.5 19.9 95 93 1-BC 13 06/16 FG-0.5 3 20.5 101.5 14.0 100 99 1-C 14 06/16 FG 2 15.0 113.5 17.3 111 98 1-A TEST LOCATION: FIRE LINE UTILITY 8 APPROXIMATLEY 20' W AND 95' N OF THE SW CORNER OF PAD 9 APPROXIMATLEY 20' N AND 20' E OF THE SW CORNER OF PAD to APPROXIMATLEY 20' N AND 25' E OF THE NW CORNER OF PAD 11 APPROXIMATLEY 20' N AND 90' E OF THE NW CORNER OF PAD 12 APPROXIMATLEY 20' N AND 95' E OF THE NW CORNER OF PAD 13 APPROXIMATLEY 20' E AND 20' S OF THE NE CORNER OF PAD 14 APPROXIMATLEY 20' E AND 25' S OF THE NE CORNER OF PAD ~ /~ ~ / 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFI N B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS pectful }+timitted C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST ALPHA T TING, INC. RE UG ERNAND , JR. ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 /~/ Dallas, Texas 75229 (972) 620-8911 MAVEX COPPELL CROSSING, LTD. TESTED FOR LEWISVILLE, TEXAS COPPELL CROSSING PROJECT COPPELL, TEXAS TEST DATA: REPORT OF FIELD COMPACTION TESTS DATE OUR REPORT NO. 06/16/98 97332-23B TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOI SURE MAXIMUM LAB DRY ~FSITY IN PLACE MOI%RE IN PLACE DRY ~~SITY PERCENT COMPACTION COMMENT' 15 06/16 FG-0.5 2 15.0 113.5 18.5 110 97 1-A 16 06/16 FG 2 15.0 113.5 15.8 100 $8 1-B TEST LOCATION: FIRE LINE UTILITY 15 APPROXIMATLEY 20' E AND 65' S OF THE NE CORNER OF PAD 16 APPROXIMATLEY 20' E AND 70' S OF THE NE CORNER OF PAD /1 i ,-. 1. FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIE TIO 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS spectfu Submitted 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST ESTING, INC. FU IO RNAN EZ, JR. CG01083-18 ~ , ~'