Coppell Cross 1P-LR 980512ALPHA TESTING, INC. 2209 Wisconsin St. ~~~ Suite 100 Dallas, Texas 75229 (214) 620-8911 TESTED FOR: MAVEX COPPELL CROSSING, LTD. LEWISVILLE, TEXAS PROJECT: COPPELL CROSSING COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE: MAY 12 , 19 9 8 OUR REPORT NO.: 97332-9 FIELD DATA LOCATION OF CONCRETE PLACEMENT PIERS : D-11, D-12 , D-13 AND D-13 DATE PLACED 0 5/ 12 / 9 8 PLANT 7 TIME 11:3 0 DELIVER TICKET NO 6 2 6 3 4 SLUMP (ASTM C-143) 4 ~ '] 5 MIX PROPORTIONS (SSD) N/A AIR CONTENT (ASTM C-231 O OR C-173 ^) (.j/A CEMENT N/A AIR TEMPERATURE 78 WATER N/A CONCRETE TEMPERATURE $5 FINE AGGREGATE N/p~ DATE RECEIVED 0 5 / 13 / 9 8 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY G . E . ADMIXTURE N/A MIX DATA SUBMITTED BY LATTIMORFr SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 R C-1231 ^ LAB NO. 13 ~ i 14 ~ 15 I 16! Specifications COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12") (ASTM C-39) TYPE DATE AGE TOTAL AREA COMPRESSIVE CURING TESTED DAYS LOAD STRENGTH, PSI LAB 05/19/9$ 7 86,583 28.27 3,060 LAB 06/09/9$ 28 28.27 LAB 06/09/98 28 28.27 LAB HOLD H 28.27 REMARKS ylinders made by ALPHA representative. ^ Cylinders made by Architect's or ntractor's representative. Cylinders picked up by ALPHA laboratory. Cylinders delivered to ALPHA laboratory. ;.~ Compressions test results comply with applicable specifications. I"~ Compression test results do not comply with applicable specifications. iu - _ _ ___ _ - _ _ _ ___ 3, O ~ d__ J Respectfully Submitted LPHA TESTING, INC. PAT STETTNER 28 ALPHA TESTING, INC. TESTED FOR: MAVEX COPPELL CROSSING, LTD. LEWISVILLE, TEXAS 2209 Wisconsin St. ~~~ Suite 100 Dallas, Texas 75229 (214) 620-8911 PROJECT: COPPELL CROSSING COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST DATE OF ISSUE: MAY 12, 1998 OUR REPORT NO.: 97332-9 FIELD DATA LOCATION OF CONCRETE PLACEMENT PIERS : D-11, D-12 , D--13 AND D-13 DATE PLACED 0 5 / 12 / 9 $ PLANT 7 TIME 11:3 0 DELIVER TICKET NO 6 2 6 3 4 SLUMP (ASTM C-143) 4 ~ 7 cj MIX PROPORTIONS (SSD) N/A AIR CONTENT (ASTM C-231 ^ OR C-173 ^) N/A CEMENT N/A AIR TEMPERATURE '] $ WATER pj/p, CONCRETE TEMPERATURE 85 FINE AGGREGATE N/A DATE RECEIVED 05 / 1319 8 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY G , E ~ ADMIXTURE N/A MIX DATA SUBMITTED BY LATTIMORE/ SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 C~,O~R C-1231 ^ COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12") (ASTM C-39) LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 13 LAB 05/19/98 7 86,583 28.27 3,060 14 LAB 06/09/98 28 112,282 2$.27 3,970 15 LAB 06/09/98 28 130,510 28.27 4,620 16 LAB HOLD H 28.27 Specifications 2$ 3, 0 0 0 REMARKS ~'Gylinders made by ALPHA representative. ^ Cylinders made by Architect's or Contractor's representative. ^ enders picked up by ALPHA a ratory. ^ Cylinders delivered to ALPHA laboratory. l~'Compressions test results comply with applicable specifications. ^ Compression test results do not comply with applicable specifications. es ul miffed A H ,INC. PAT STETTNER COM PUDATA-CG01083-34