Loading...
Grand Cove-LR 940725Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS CLIENT: Frank Bamburg Building Co. PROJECT: Grand Cove Estates, Coppell, TX LOCATION OF POUR SET 1: Storm sewer line "A headwall footings, Station 0 +68 LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. Cement Ticket No. Flyash Time Batched Sand Time Sampled in. Concrete Temp. (ASTM c1064) 1.0 in. Air Content (ASTM 0231) Water Unit Weight (ASTM C1381 Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM cis) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28 -Day (ASTM C143) psi Strength 10 7 08/01/94 115,900 4100 11 28 08/22/94 12 28 08/22/94 NOTE: Cylinders and all information furnished by contractor. TECHNICIAN: Contractor DISTRIBUTION: (1) Frank Bamburg Building Co., Frank Bamburg (1) C. W. Young Construction (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 JOB NO.: 94.1075 DATE: 25 July 1994 SUPPLIER: 28 -Day Average 3000 fl,,:eily.411-.11 (214) 351 -6419 Fax (214) 351 -5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 94.1075 CLIENT: Frank Bamburg Building Co. DATE: 25 July 1994 PROJECT: Grand Cove Estates, Coppell, TX SUPPLIER: LOCATION OF POUR SET 1: Storm sewer line "A headwall footings, Station 0 68 LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. Cement Ticket No. Flyash Time Batched Sand Time Sampled in. Concrete Temp. (ASTM C1064) 1.0 in. Air Content (ASTM C231) Water Unit Weight (ASTM C138) Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28 -Day (ASTM C143) psi Strength 10 7 08/01/94 115,900 4100 11 28 08/22/94 123,800 4380 12 28 08/22/94 121,900 4310 28 Day Average 4350 NOTE: Cylinders and all information furnished by contractor. TECHNICIAN: Contractor DISTRIBUTION: (1) Frank Bamburg Building Co., Frank Bamburg (1) C. W. Young Construction (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 3000 (214) 351 -6419 Fax (214) 351 -5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF CONCRETE TESTS JOB NO.: 94.1075 CLIENT: Frank Bamburg Building Co. DATE: 25 July 1994 PROJECT: Grand Cove Estates, Coppell, TX SUPPLIER: LOCATION OF POUR SET 1: Concrete paving patch at Bethel School Road, sanitary sewer line A, Station 0+10 LOCATION OF POUR SET 2: SAMPLE DATA: SET 1 SET 2 MIX NO. Truck No. Cement Ticket No. Flyash Time Batched Sand Time Sampled in. Concrete Temp. (ASTM C1064) 1.0 in. Air Content (ASTM C231) Water Unit Weight (ASTM C138) Admix #1 Admix #2 AEA COMPRESSIVE STRENGTH TESTS (ASTM C39) (Standard 6 inch x 12 inch cylinder) Cylinder Slump Age Test Total Load Compressive Required Number Inches Days Date Pounds Strength 28 -Day (ASTM C143) psi Strength 13 4 07/29/94 131,200 4640 14 7 08/01/94 136,800 4840 15 28 08/22/94 159,400 5640 16 28 08/22/94 156,600 5540 28 -Day Average 5590 NOTE: Cylinders and all information furnished by contractor. TECHNICIAN: Contractor DISTRIBUTION: (1) Frank Bamburg Building Co., Frank Bamburg (1) C. W. Young Construction (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 3000 l ih.(4*)/e4Q .Suppk (214) 351 -6419 Fax (214) 351 -5148 Hooper Engineering Laboratories, Inc. Construction Materials Testing REPORT OF IN -PLACE DENSITY TESTS CLIENT: Frank Bamburg Building Co. DATE: 25 July 1994 PROJECT: Grand Cove Estates, Coppell, TX JOB NO.: 94.1075 MATERIAL DESCRIPTION: 1) On -Site Fill Tan Sand with Grey Clay ASTM D 698 STANDARD PROCTOR: 1) 1 13.0 pcf 12.0% Moisture MOISTURE DRY PERCENT REQUIRED LOCATION PROCTOR LIFT CONTENT DENSITY COMPACTION COMPACTION Backfill Over Water Lines 21) Wales Ct., Block A, Lot 10 1 Fin. Sub. 10.2 109.0 96.5 95 22) Wales Ct., Block A, Lot 16 1 Fin. Sub. 1 1 .0 109.4 96.8 Optimum 2% 23) Wales Ct., Block A, Lot 22 1 Fin. Sub. 12.1 113.9 100.8 TECHNICIAN: CDJ DISTRIBUTION: (1) Frank Bamburg Building Co., Frank Bamburg (1) C. W. Young Construction (1) City of Coppell, Garreth Campbell 2870 Walnut Hill Lane Dallas, Texas 75229 PCF 1 444.• daisw•—. (214) 351 -6419 Fax (214) 351 -5148