Loading...
CF-Justice Center-LR 960925 ATEC Associates, Inc. 11356 Mathis Avenue Dallas, Texas 75229 (972)556-2204 METRO 263-1681 REPORT OF CONCRETE COMPRESSION TEST Project: Coppell Justice Center Date Sampled: 09/25/96 Client: City of Coppell Our Report No: 25-02-96-00068.53A Field Test Data Location of Pour when Sampled: Sidewalk - 25' N and 40' E of NE Comer of Building. Contractor: Mid South Sampled By: J. Travis Time: Batched: 6:17am Temperature: Air: 70°F Slump: 4.75 in. Sampled: 7: loam Concrete: 79°F Air Content: 4.0% Compressive StrenEth Test Results Supplier/Plant: Delivery Ticket No.: Truck Number: Load Size: Mix ID No.: Water Added on site: Mid Cities Ready-Mix 18980 444 10 cu.yds. 31 -- gals. Specimea Type:_ 6" X 12" Test Method: A5TM C-34, ASTM' GE231 x ASTM C-617 Se! ~. Speelmea No. Type Cnrfng Date Tested Age Daps Failure Load, Ibs. Specimen Area (sq. in.) Compressive Strength, PSI I 4739 Lab 10-02 7 122,760 28.27 4,340 I 4740 Lab 10-23 28 164,140 28.27 5,810 1 4741 Lab 10-23 28 154,180 28.27 5,450 t 4742 Lab 10-23 Hold SPECIFIED STRENGTH 28 3,000 Remarks: Cylinder diamter = 6.00 unless noted otherwise. Respectfully submitted, i This report represents only the materials tested and may or y nef be r resentative of identical or similar materials. This report shall not be reproduced except in its entirety an w' the a ress written permission of ATEC Associates, Inc.