CF-Justice Center-LR 960905~~3/
D~(~~~~
ATEC Associates, Inc. O C r I
11356 Mathis Avenue kE~~l7
Dallas, Texas 75229
(972) 556-2204 ~opp~~ p~1~IIC~I~
METRO 263-1681
REPORT OF CONCRETE COMPRESSION TEST
Project: Coppel Justice Center Date Sampled: 09/05/96
Client: City of Coppell Our Report No: 25-02-96-00068.52A
Wield Test Data
Location of Pour when Sampled: Sidewalk - 8' E and 10' S of NW Comer of Building.
Contractor: Mid South Supplier/Plant: Mid Cities Ready-Mix
Sampled By: L. Ratcliff Delivery Ticket No.: 19257
Time: Batched: 12:30 Sampled: 2:OOpm Truck Number: 549
Temperature: Air: 85°F Concrete: 93°F Load Size: 10 cu.yds.
Slump: 4 in. Air Content: --% Mix ID No.: /131
Water Added on site: -- gals.
Compressive Strength Test Results
Specimen Type: cubs 6" X Iz~~ Test 14feihod: ASTM C-39, ASTM c~1231 x_____ ASIlvI C-617
Set
lwe. Specimen No. Tape
Curing Date Tested Age Days Failnrc Load, Ibs. Specimen Area jsq.
in.) Compressive
',Strengfh,-PSI
1 4027 Lab 09-12 7 79,060 28.27 2,800
1 4028 Lab 10-03 28 108,160 28.27 3,830
1 4029 Lab 10-03 28 101,280 28.27 3,580
1 4030 Lab 10-03 Hold
SPECIFIED STRENGTH 28 3,000
Remarks: Cylinder diamter = 6.00 unless noted otherwise.
Respectfully submitted,
This report represents only the taterials tested and may or~y 1 of be representative of identical or similaz materials.