CF-Justice Center-LR 960905~~3/ D~(~~~~ ATEC Associates, Inc. O C r I 11356 Mathis Avenue kE~~l7 Dallas, Texas 75229 (972) 556-2204 ~opp~~ p~1~IIC~I~ METRO 263-1681 REPORT OF CONCRETE COMPRESSION TEST Project: Coppel Justice Center Date Sampled: 09/05/96 Client: City of Coppell Our Report No: 25-02-96-00068.52A Wield Test Data Location of Pour when Sampled: Sidewalk - 8' E and 10' S of NW Comer of Building. Contractor: Mid South Supplier/Plant: Mid Cities Ready-Mix Sampled By: L. Ratcliff Delivery Ticket No.: 19257 Time: Batched: 12:30 Sampled: 2:OOpm Truck Number: 549 Temperature: Air: 85°F Concrete: 93°F Load Size: 10 cu.yds. Slump: 4 in. Air Content: --% Mix ID No.: /131 Water Added on site: -- gals. Compressive Strength Test Results Specimen Type: cubs 6" X Iz~~ Test 14feihod: ASTM C-39, ASTM c~1231 x_____ ASIlvI C-617 Set lwe. Specimen No. Tape Curing Date Tested Age Days Failnrc Load, Ibs. Specimen Area jsq. in.) Compressive ',Strengfh,-PSI 1 4027 Lab 09-12 7 79,060 28.27 2,800 1 4028 Lab 10-03 28 108,160 28.27 3,830 1 4029 Lab 10-03 28 101,280 28.27 3,580 1 4030 Lab 10-03 Hold SPECIFIED STRENGTH 28 3,000 Remarks: Cylinder diamter = 6.00 unless noted otherwise. Respectfully submitted, This report represents only the taterials tested and may or~y 1 of be representative of identical or similaz materials. This report shall not be reproduced except in its entirety an the express written permission of ATEC Associates, Inc.