REPORT OF CONCRETE COMPRESSION TEST
Project: Coppell Justice Center Date Sampled: 07/08/96
Client: City of Coppell Our Report No: 25-02-96-00068.46A
Field Test Data
Location of Pour when Sampled: Dempster Enclosure Grid Beam
Contractor Duratex Construction Supplier/Plant: Mid-Cities Ready-Mix
Sampled By: C. Delgado Delivery Ticket No.: 16581
Time: Batched: 12:45 am Sampled: 1:43 Truck Number: 446
Temperature: Air: 98°F Concrete: 102°F Load Size: 7 cu.yds.
Slump: 4.5 in. Air Content: ---~ Mix ID No.: Mix 9351
Water Added on site: 0 gals.
Compressive Strength Test Results
Specimen Type: Cylinder 6" X 12" Test Method: ASTM ~-3$ ASTM C-1231. ASTM C-617
Set
No, ' Specimen'No. Type
Curing Date Tested Age Days. Failure Load, Ibs. Specimen Area (sq.
in.} Compressive
Strength, PSI
1 1983 lab 07-15 7 84,160 28.27 2,980
1 1984 Lab 08-OS 28 113,580 28.27 4,020
1 1985 lab O8-OS 28 107,840 28.27 3,810
1 1986 Lab 08-OS Hold
SPECIFIED STRENGTH 28 3,000
Remarks: Cylinder diameter = 6.00 in. unless noted otherwise.