Loading...
CF-Justice Center-LR 960626ATEC Associates, Inc. 11356 Mathis Avenue Dallas, Texas 75229 (214)556-2204 METRO 263-1681 Project: Client: Coppel Justice Center City of Coppell .`"' ~ ~ ~. crh_~ 0 r~ ~ctt;'D Date Sampled: 06/26/96 Our Report No: 25-02-96-00068.44 Field Test Data Location of Pour when Sampled: North West Curb Contractor Mid South Contractors Supplier/Plant: Redi/Mix 2 Sampled By: C. Delgado Delivery Ticket No.: 27911 Time: Batched: 10:10 pm Sampled: 11:20 Truck Number: 106 Temperature: Air: 82°F Concrete: 96°F Load Size: 9 cu.yds. Slump: 4.75 in. Air Content: 4.7 % Mix ID No.: 720 Water Added on site: 0 gals. Compressive Strength Test Results Specimen Type: Cyr. 6" X 12" Test Method: ASTM C-39; ASTM C-1231 X ASTM C-617 Set -No. Specimeu No. Type Curing Date Tested Age Days Failure Load, Ibs. Specimen Area (sq. inJ Compressive Strengths PSI 1 1847 Lab 07-03 7 57,040 28.27 2,020 1 1848 Lab 07-24 28 87,340 28.27 3,090 1 1849 Lab 07-24 28 79,220 28.27 2,800 1 1850 Lab 08-21 56 102,820 28.27 3,640 SPECIFIED STRENGTH 28 3,000 Remarks: Cylinder diameter = 6.0 in. unless noted otherwise. Respectfully submitted, This report represents only the materials tested and maylo~ay not be rEpresentative of identical or similar materials. This report shall not be reproduced except in its entirety`~nd with the express written permission of ATEC Associates, Inc. f~3 i ATEC Associates, Inc. 11356 Mathis Avenue Dallas, Texas 75229 (214)556-2204 METRO 263-1681 REPORT OF CONCRETE COMPRESSION TEST Project: Coppel Justice Center Date Sampled: 06-26-96 Client: City of Coppell Our Report No: 25-02-96-00068.44A Field Test Data Location of Pour when Sampled: 1st four layers above window at SW comer of building. Contractor: Mid South Construction Supplier/Plant: On Site Sampled By: J. Travis Delivery Ticket No.: ------ Time Batched: 11:10 Sampled: 11:18 Truck Number: ---- Temperature: Air: 88°F Concrete: -- °F Mix ID No.: Type N Slump: --- in. Air Content: -- % Load Size: --- cu. yds. Water Added on site: --- Compressive Strength Test Results Specimen Tgpe: Cubes 2" X 2" Test Method: ASTM C-39, ASTM C-1231. ASTM C-617 Set No. Specimen No. Type Curigg Date Tested Age Days Failure Laad, Ibs. Specimen Area {sq. in.) Compressive Strength, PSI 2 1851 Lab 07-03 7 2800 4.0 700 2 1852 Lab 07-24 28 3620 4.0 910 2 1853 Lab 07-24 28 4300 4.0 1080 SPECIFIED STRENGTH 28 750 Remarks: This report represents only the materials tested and may or ma~i Cbe representative of identical or similar materials. This report shall not be reproduced except in its entirety and with the express written permission of ATEC Associates, Inc.