REPORT OF CONCRETE COMPRESSION TEST
Project: Criminal Justice Center Date Sampled: 05/15/96
Client: City of Coppell Our Report No: 25-02-96-00068.31
Field Test Data
Location of Pour when Sampled: Holding Cells, CMU Walls F to G & 1 to 1.7
Contractor I7t><ratex Const. Supplier/Plant: Site
Sampled By: A. Rodriquez Delivery Ticket No.: ---
Time: Batched: 11:00 Sampled: 11:00 Truck Number: --- Load Size: -- cu.yds.
Temperature: Air: 78°F Concrete: 88°F Mix ID No.: Type 'S'
Stump: 3.0 in. Air Content: --% Water Added on site: -- gals.
Compressive Strength Test Results
Specimen Type: Cyt. 2° X 2" X' 2" Test Method: ASTM C~9, ASTM C-1231 ASTM 6-617
Set
No. Specimen No. Type
Cueing Date Tested Age Days Faihire Load,
Ibs. Specimen Area
(sq. in.) Compressive
Strength,. PSI
1 1270 Lab OS-22 7 11,860 4.0 2,970
1 1271 Lab 06-12 28 14,300 4.0 3,575
1 1272 Lab 06-12 28 13,460 4.0 3,370
SPECIFIED STRENGTH 28 1.~