CF-Justice Center-LR 960320ATEC ASSOCiAteB, InC. 11356 Mathis Avenue Dallas, Texas 75229 (214) 556-2204 METRO (214) 263-1681 FIELD DENSITY TESTS Project Name: Criminal Justice Center Client Name: City of Coppell Test Moisture ;C" Dry_Density Proctor ~: of,Proctor Pass Fail. Fail Elevation/ Location No. (PCF).- No. Spec Actual Compaction Moisture Refer F.G. Srid Coordinates or Roadway Station 1 8.5 120.2 12630 95 103.1 X F.G. Sanitar Col. Line F.8 At 1.5 2 10.5 117.6 12630 95 100.9 X F.G. Sanitar Col. Line G.8 At 1.5 3 9.5 116.1 12630 95 99.6 X F.G. Grade Beam Col. Line C.8 At 4 4 10.8 111.5 12630 95 95.6 X F.G. Grade Beam Col. Line A.3 At 14 Test De th 1 6" 2 6" 3 6" 4 6" Moisture Std. Count Density Std. Count Gauge Number Model Densit Count 2257 2279 2473 2641 Moisture Count 130 152 138 149 657 2837 24084/3430 Wet Density (PCF) 130.4 129.9 127.1 123.5 Test Method Moisture <PCF) 10.3 12.3 11.0 12.0 ASTM: D2922, Direct Transmission _X_ Back Scatter _ ASTM: D3017 General Contractor: Mid South ATEC Jab No_: 25-a2-9fr000G8.Z0 Date: 03/20/% (1) Test Location Established by: Grid Lines _ Control Points _ Estimation (2) Depth or Elev. of Test Established by: Survey _ Grade Stakes _ Estimation (3) Test Conducted on: Full Time Basis _ Intermittent Basis _X_ Proctor No. Maximum Density (PCF) Opt. Moisture (X) Std. Proctor 12630 116.6 10.8 X Remarks ATEC REPRESENTATIVE: P. McClure _X Contractor X Contractor Mod. Proctor Visual Description Respectfully Submitted, "E~'~ Zl-' This report represents only the materials tested and may or may not be representstive of identical or similar materials. This report shall not be reproduced except in its entirety and with the express written permission of ATEC Associates, Inc.