CF-Justice Center-LR 960304yo3i ATEC Associates, Inc. 11356 Mathis Avenue Dallas, Texas 75229 (214) 556-2204 METRO 263-1681 REPORT OF CONCRETE COMPRESSION TEST Project: Criminal Justice Center Date Sampled: 03/04/96 Client: City of Coppell Our Report No: 25-02-96-00068.12 Field Test Data Location of Pour when Sampled: Grade Beam Col Linee 1 From G.4 To F Contractor Duratex Supplier/Plant: Redi-Mix Sampled By: P. McClure Delivery Ticket No.: 109647 Time: Batched: 12:30 Sampled: 2:20 Truck Number: 125 Load Size: 9 cu.yds. Temperature: Air: 66°F Concrete: 58°F Mix ID Nn.: 723 Slump: 4.5 in. Air Content: ---k Water Added on site: 0 gals. Compressive Strength Test Results Specimen Typo Cyt: b" X 12" Test Me16od: ASTM C-39, ASTbt C-1231 X ASTM C-6l? SeC No. Specimen No. Type Curing ' Date Tested Age Days Failure load, lbs. Specimen Area (sq, in.) Compressive Strength, PSI 1 %27 Lab 03-11 7 107,1180 28.27 3,790 l %28 lab 04-O1 2R 129,7611 28.27 4,590 I 9629 Lab 04-01 2R 128.160 28.27 4,530 1 %30 Lab 04-01 Hold SPECIFIED STRENG"fH 28 3•~ emar c• ~ ,n er Iameter = In. unless noted otherwise. Respectfully submitted, f ~~~' This report represents only the materials tested and may or may not be representative of identical or similar materials. This report shall not be reproduced except in its entirety and with the express written permission of ATEC Associates, Inc. ATEC Associates, Inc. 11356 Mathis Dallas, Texas 75229 (214)556-2204 METRO 263-1681 PROJECT: Criminal Justice Center CLIENT: City of Coppell PROJECT INSPECTION REPORT Job No.: 25-02-96-00068.12A Date: 03/04/96 REMARKS: A representative of ATEC Associates visited the proiect site to perform lime gradations and to obtain a proctor sample #1 North Parkin Lot #2 South Lot 9 1 Lb Sample 10 3 Lb Sample 5.7 Lb. Retained 5.9 Lb. Retained 3 4 Lb Passim = 37% Passim #4 4 4 Lb Passim = 43% Passin¢ #4 is 60% passing #4 and 100% passim 1 3/4" sieve Two soil samples were obtained for proctor analysis. ATEC REPRESENTATIVE: P. McClure Respectfully submitted, ~-`~ --- ATEC ASSOCistes, InC. (214) 556-2204 11356 Mathis Avenue Dallas, Texas 75229 METRO (214) 263-1681 Project Nance: Client Name: Criainal Justice Center City of Cappell FIELD DENSITY TESTS General Contractor: Mid South Date: 03-04-% ATEC Jab No.: 25-02-96-00068.128 Test Moisture ;C Dry Density Proctor 7, of Proctor Pass fail Fail. Elevation/ Location No. (PCF) No. Spec Actual Cowaction Moisture Reter F.G. Grid €oordinates or Raaduay Station 1 7.5 113.2 12630 95 97.1 X -12" Grade Beam Backfill G-5 2 9.3 113.8 12630 95 97.5 X -12" Grade Beam Backfill J-3.3 3 11.5 116.5 12646 95 99.8 X -12" Grade Beam eackfill J-1.8 Test Depth 1 6" 2 6" 3 6" Densit Count 2457 2297 2014 Moisture Count 102 124 152 Moisture Std. Count Density Std. Count Gau a Number Model 558 2500 8558/3411-B Wet Densit (PCF) 121.7 124.4 129.9 Test Method ASTM: D2922, Direct Transmission _X_ Back Scatter _ Moisture (PCF) 8.7 10.6 13.4 ASTM: D3017 (1) Test Location Established by: Grid Lines _ Control Points _ Estimation _X_ Contractor (2) Depth or Elev. of Test Established by: Survey _ Grade Stakes _ Estimation _X_ Contractor _ (3) Test Conducted on: Full Time Basis Intermittent Basis Proctor No. Maximum Density (PCF) Opt. Moisture (X) Std. Proctor Mod. Proctor Visual Description 12630 116.6 10.8 X Red Tan Clav Sand (Select) Remarks: Respectfully Submitted, ATEC REPRESENTATIVE: B. Holt 'Ibis report represents only the materiels tested and may or may not be representative of identical or similar materials. This report shall not be reproduced except in its enti rety aced with the express written permission of ATEC Associaus, Inc.