CF-Justice Center-LR 960216Q~6ea~¢0 ATEC Associates, Inc. MAR 2 2 REI:'il 11356 Mathis Avenue ~j®~s° ~dab~ i.t'®~II~ttb Dallas, Texas 75229 ~s' (214)556-2204 METRO 263-1681 REPORT OF CONCRETE COMPRESSION TEST Project: Coppell Justice Center Date Sampled: 02-16-96 Client: City of Coppell Our Report No: 25-02-95-00068.08E Field Test Data Location of Pour when Sampled: Piers J.6-3.3, K-3.1, J-3.1, H-3.1 Contractor Duratex Construction Supplier/Plant: Redi-Mix Sampled By: B. Holt Delivery Ticket No.: 98236 Tune: Batched: 11:25 Sampled Truck Number: 110Load Size: 9 cu. yds Temperature: Air: 49°F Concrete 60°F Mix ID No.: 723 Slump: 4.5 in. Air Content ---4b Water Added on site: 0 gals. Compressive Strength Test Results Specimen Typc._CyM. 6" X 12" `Test Melbod: ASTM C-39, ASTM C-1231 X ASTM C-617 Set No. Specimen No. Typr Curing Date Tested Age Daya Failure Load. Iba. Specimen Ares (sq. inJ' Compra+ive Strength; PSl 1 9193 Lab 02-23 7 94,540 28.27 3,340 1 9194 Lab 03-IS 28 122,680 28.27 4,340 1 9195 Lab 03-IS 28 123,520 28.27 4,370 1 9196 Lab 03-IS Hold SPECIFIED STRENGTH 28 3,~ Remarks: Cylinder diameter = 6.00 in. unless noted otherwise. Respectfully submitted, ~^ This report represents only the materials tested and may or may not be representative of identical or similar materials. This report shall not be reproduced except in its entirety and with the express written permission of ATEC Associates, Inc.