Loading...
CF-Justice Center-LR 960215~3~ ATEC Associates, Inc. 11356 Mathis Avenue Dallas, Texas 75229 (214) 556-2204 METRO 263-1681 RFPnRT OF CONCRETE COMPRESSION TEST Project: Criminal Justice Center Date Sampled: 02/15/96 Client: City of Coppell Our Report No: 25-02-96-OOOG8.07C Field Test Data Location o[ Pour when Sampled: Piers D.1-6, D.5-b, E-6, E-5, E.5-5 Contractor Duratex Construction Supplier/Plant: Redi-Mix Sampled By: B. Holt Delivery Ticket No.: 98179 Tinne: Batched: 1:33 Sampled: 2:25 Truck Number: Load Size: 9 cu.yds. Temperature: Air: 66°F Concrete: 68°F Mix ID No.: 5 Sack X723 Sh~mp: 4.5 in. Air Content: --% Water Added on site: 0 gals. om~ressive Strength Test Results s~a~.7>~_c~t cN x iz• r~ ~1uoa: ~s~l c-39, ' As'1'M c.c231 _x ~s~ c-~iz Sec No. Specimen No. 7~pe cariuL - I)ateTa+ted ', Ape Days F'u'ture Load, Iba. ' ' Specimen Ara (aq. ie.j', Comprnalve Sc,rnaih, Psi 1 9162 Lab 02-22 7 96,120 28.27 3,400 1 9163 Lab 03-14 28 123,600 28.27 4,370 1 9164 Lab 03-14 28 116,320 28.27 4,110 1 9165 Lab 013-14 Hold SPECIFIED STRFNC3rH 28 3+~ Pmar c• v 111 er lameter = ln. un ess noted otherwise. Respectfully submitted, ~ z~ i This report represents only the materials tested and•- y or may not be representative of identical or similar materials. This report shall not be reproduced except in its entirety and with the express written permission of ATEC Associates, Inc.