Loading...
Gateway BP(3.1)-LR070329Fone Engineering NO Client: Transwestem Commercial Sege Mr. Ric Nelson Transwestem Comipetcial Services 5001 Spring Vy Rd., Ste 600W Dallas TX 7 Project: Gate Business Center C e11, Texas 1 TEST NO Services: Perform In -Place Density Test in accordance with ASTM Standards. CONTRACTOR: Constructors Associates Test Methods: ASTM D -2922 ASTM D -3017 Tannish Brown Silty Clay TEST LOCATION Fill 1 Building pad 1, southwest corner, 25' north, 35' east, 4th lift Fill 2 Building pad 1, southwest corner, 25' north, 70' east, 4th Lift Fill 3 Building pad 1, southwest corner, 25' north, 110' east, 4th lift Fill 4 Building pad 1, southwest corner, 75' north, 35' east, 4th lift Fill 5 Building pad 1, southwest corner, 75' north, 70' east, 4th lift PROJECT DATA Gauge: Troxler 3430 Gauge Serial No: 35518 Test Mode: DT Previous: 744 MOISTURE DENSITY RELATIONS MJD No. Description Moisture /o Maximum Density pcf 24.5 93.5 FIEI,I) DENSITY TESTS 8908 Ambassador Row, Dallas, TX 75247 7701 W. Little York, Suite 600, Houston, TX 77040 4221 Freidrich Lane, Suite 195, Austin, TX 78744 Corporate Phone: (817) 284 -1318 IN -PLACE DENSITY TESTING Report No.: Project No.: Date of Service: Report Date: 278383 0712786 02/10/2007 03/29/2007 Standard Counts Moisture Density Current: 742 Current: 2564 Project Requirements Moisture Density Minimum +4 Previous: 2566 PROBE M/D MOISTURE WET DENSITY DRY DENSITY DEPTH No. (pcf) (pcf) 6" 1 32.4 6 1 33.7 6" 1 33.2 6" 1 34.4 6" 1 32.5 116.8 116.7 116.7 116.8 116.1 92 -96 DENSITY max) 88.2 94 87.3 93 87.6 94 86.9 93 87.6 94 1/ 1 07 LIMTI'ATIONS: The test results presented herein were r p epared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. TM Page 1 of 2