Loading...
Food Lion-LR 900829GEOTECHNICAL INVESTIGATION for Food Lion, Store No. 6A Sandy Lake @ Samuel Blvd. Coppell, Texas ALPHA REPORT NO. 90238 ALPHA TESTING, INC. An 4;cnc Services Gicuo ComPCTIY 22Cy Nsccnsrn St. Suite TC0 -c!res "excs 15229 2'- %_ZC -8 AAX 2 ?414C64023 August 29, 1990 Artech Design Group 1303 Walnut Hill Lane, Suite 130 Irving, Texas 75038 Attention: Mr. Rory Chen, AIA Re: Geotechnical Investigation Food Lion, Store No. 6A Sandy Lake @ Samuel Blvd. Coppell, Texas ALPHA Report No. 90238 Gentlemen: Submitted herewith is the report of our geotechnical investigation at the site of the referenced project. This study was authorized by Mr. Rory Chen, AIA, in accordance with our proposal agreement dated August 21, 1990. This report contains the results of our findings, an engineering interpretation of these with respect to the available project characteristics and recommendations to aid desicn and construction of foundations and other earth connected phases of this project. We appreciate the opportunity to be of service to you on this project. If we can be of further assistance, such as providing our materials testing services during construction, please contact our office. Very truly yours, w I L I : ALPHA EST ING, IIN C . vid A. Lewis, P.E. Manager of Engineering Services Jim L. Hillhouse, P.E. President Copies: (4) Client Alpha Report No. 90238 Although movements are estimated to be within tolerable limits for structural safety, such movements could be detrimental to the slab if it were rigidly connected.-to the foundation. Floor slabs which are dowelled into the perimeter grade beam typically develop a plastic hinge (crack) -.parallel to and approximately five to ten ft inside of the building perimeter. The plastic hinge may be controlled by constructing a joint in the floor slab in the area of the anticipated hinge location. There may be certain areas where it will be difficult or impractical to make the slab floating. In such areas, it may be necessary to increase the slab thickness and 'reinforcement to prevent the foundations from cracking the slab and settling independently. In addition, a moisture barrier of polyethylene sheeting or similar material should be placed between the slab and subgrade soils to retard moisture migration through the slab. 6.4 Pavements The sandy clay or clayey sand soils encountered near the existing ground surface will probably constitute the subgrade for most of the parking and drive areas. Therefore, it is 12 Alpha Report No. 90238 recommended that these soils be improved prior to construction of the pavements. It is recommended that the existing sandy clay or clayey sand soils in drive and parking areas be graded to achieve final subgrade elevation. The exposed surface of the sandy clays should be scarified to a depth of at least 6 inches and then be compacted to at least 98 percent of Standard Proctor maximum dry density (ASTM D 698) at /or slightly above the optimum moisture content. California Bearing Ratio (CBR) tests have not been performed for this specific project, but our previous experience with similar soils indicates that the CBR value for existing sandy clay or clayey sand will be in the range of 8 to 10. Using the above CBR value, and assuming normal traffic for a 15 —year project life, we provide the following pavement design for parking and drive areas provided traffic will consist of cars and occasional light trucks. Pavements could then consist of 5 inches of adequately reinforced concrete in both light duty and heavy truck traffic areas. Theoretically, a thinner pavement section is possible in the light traffic area, however, to provide adequate concrete cover for the reinforcing steel, a 5 inch pavement section is required. 13 js Alpha Report No. 90238 The calculations used to determine the required pavement thickness are based only on the physical and engineering properties of the materials and conventional thickness determination procedures. Related civil design factors such as subgrade drainage, shoulder support, cross - sectional configurations, surface elevations, reinforcing steel, joint design and environmental factors will significantly affect the service life and must be included in the preparation of the construction drawings and specifications. 6.5 Pavement Specifications Pavements should be specified, constructed and tested to meet the following requirements: 1. Portland Cement Concrete - Texas SDHPT Item 360. Specify a minimum compressive strength of 3,000 lbs. per sq inch. 2. Recompacted Subgrade - on -site sandy clay and /clayey sand materials should be scarified to a depth of 6 inches and recompacted to at least 98 pet.:cent of ASTM 698 at /or slightly above the optimum moisture. 14