Loading...
St Ann Catholic-LR070424CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061334.0045 Service Date: February 26, 2007 Irerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630 -1010 Client: St Ann Catholic Church Attn: Jennifer Lindsey 180 Samuel Blvd Coppell TX 75019 Report Date: April 24, 2007 Project: St. Ann Catholic j New Additio 180 Sa Blvd. Cop TX Project No.: 914 1334 Material Information Specified Strength: 3000 psi @ 28 Days Batch Time: 11:56 AM Plant: 7 Supplier: Lattimore Materials Co Truck No: 1093 Ticket No: 7175840 Mix I.D. No.: 1261 Water Added Onsite Before Test: OGallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 3.00 Air Content, %: 3.5 Concrete Temperature, oF: 71 Ambient Temperature,OF: 74 Plastic Unit Weight, pcf: 151.0 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (s q. inches 1 1 6.00 28.27 1 2 6.00 28.27 1 3 6.00 28.27 Date Ca%/ ' February 26, 2007 Time: 1:00 PM Sampledby: Gregory C. Martin J ac er Conditions: Sunny mulative Yards: 10/10 ement Method: Direct Discharge Sample Locations: Noted on sketch Placement Location: Sidewalk, SE corner of Church & W side of Shop Center, refer to attached sketch Specification 3 -6 3 -6 Test Metho ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (da)s (lbs) (psi) 03/05/2007 7 104,840 3,710 03/26/2007 28 135,370 4,790 03/26/2007 28 136,910 4,840 Average (28 Days) 4,820 1 4 6.00 28.27 04/23/2007 56 141,570 5,010 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Field Results Reported To:Gary Terracon Rep: Gregory C. Martin Report Distribution: (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Southerland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 Flaeemen. !D "2 _z 6 -,z 067 TERRACON REPORT NO.