St Ann Catholic-LR070323CONCRETE COMPRESSIVE STRENGTH TEST
Report Number: 94061334.0048
Service Date: March 15, 2007
Ireirracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(21 4) 630 -1010
Client: Report Date: March 23, 2007
St Ann Catholic Chu Project: St. Ann Catholic Parish
Attn: Jennifer Li ey New Addition
180 Samuel d 180 Samuel Blvd.
Coppell T 5019 Coppell, TX
Project No.: 94061
Material Information
Specified Strength: 4000 psi @ 28 Days
Batch Time: 12:24 PM Plant: 7
Supplier: Lattimore Materials Co.
Truck No: 1125 Ticket No: 7176508
Mix I.D. No.: 1701
Water Added Onsite Before Test: 0 Gallons
Water Added Onsite After Test: 10 Gallons
Field Test Data
Sample Information
Date Cast: March 15, 2007 Time: 1:10 PM
Sampled by: Polikarp J. Labecki
Weather Conditions: Sunny
Accumulative Yards: 10/10
Placement Method: Direct Discharge
Sample Locations: E curb
Placement Location: Paving, Road between church & new
addition
Test
Result
Specification Test Metho
Slump, inches:
3.75
- ASTM C143
Air Content, %:
3.5
- ASTM C231
Concrete Temperature, OF:
78
- ASTM C1064
Ambient Temperature,OF:
77
ASTM C1064
Plastic Unit Weight, pcf:
148.7
ASTM C138
Laboratory Test Data
Set Specimen Diameter Area
No. ID (inches) (s q. inches
1 1 6.00 28.27
2
3
Age at
Maximum Compressive
Date Test
Load Strength
Tested (da s
(lbs) (psi)
03/22/2007 7
122,220 4,320
04/12/2007 28
04/12/2007 28
1 4 05/10/2007 56
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Terracon Rep: Polikarp J. Labecki
Report Distribution:
(1) St Ann Catholic Church (1) TechniSiructures
(1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by:
(1) City of Coppell TX A. Bulent Ethem, P.G.
(1) Page Southerland Page Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 01-0DR/R01 -FWxa N.y