Loading...
St Ann Catholic-LR070323CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061334.0048 Service Date: March 15, 2007 Ireirracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (21 4) 630 -1010 Client: Report Date: March 23, 2007 St Ann Catholic Chu Project: St. Ann Catholic Parish Attn: Jennifer Li ey New Addition 180 Samuel d 180 Samuel Blvd. Coppell T 5019 Coppell, TX Project No.: 94061 Material Information Specified Strength: 4000 psi @ 28 Days Batch Time: 12:24 PM Plant: 7 Supplier: Lattimore Materials Co. Truck No: 1125 Ticket No: 7176508 Mix I.D. No.: 1701 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 10 Gallons Field Test Data Sample Information Date Cast: March 15, 2007 Time: 1:10 PM Sampled by: Polikarp J. Labecki Weather Conditions: Sunny Accumulative Yards: 10/10 Placement Method: Direct Discharge Sample Locations: E curb Placement Location: Paving, Road between church & new addition Test Result Specification Test Metho Slump, inches: 3.75 - ASTM C143 Air Content, %: 3.5 - ASTM C231 Concrete Temperature, OF: 78 - ASTM C1064 Ambient Temperature,OF: 77 ASTM C1064 Plastic Unit Weight, pcf: 148.7 ASTM C138 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (s q. inches 1 1 6.00 28.27 2 3 Age at Maximum Compressive Date Test Load Strength Tested (da s (lbs) (psi) 03/22/2007 7 122,220 4,320 04/12/2007 28 04/12/2007 28 1 4 05/10/2007 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Polikarp J. Labecki Report Distribution: (1) St Ann Catholic Church (1) TechniSiructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Southerland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 01-0DR/R01 -FWxa N.y