Northlake 635(7)-LR060920done Engineering 8908 Ambassador Row, Dallas, TX 75247 4221 Freidrich Lane, Ste 195, Austin, TX 78744 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630-9745 IN-PLACE DENSITY TESTING Client: Constructors & Associates Report No.: 265719 Mr. Bill Homrighausen Project No.: 0612080 333 Welborn Street, Ste. 200 Date of Service: 09/08/2006 Dallas TX 75219-5104 Report Date: 09/20/2006 Project: CFC Building Addition 1333 Crestside Services: Perform In-Place Density Test in accordance with ASTM Standards. PROJECT DATA CONTRACTOR: CFC Building Standard Counts Gauge: Troxler 3430 Moisture Density Test Methods: ASTM D-2922 ASTM D-3017 gauge Serial No: 32719 Current: 604 Current: 2719 Test Mode: DT Previous: 624 Previous: 2733 MOISTURE DENSITY RELATIONS Maximum M/D No. Description Moisture % Density pcf 1 Dark & Light Brown Sandy Clay w/ Concrete 19.5 101.0 Pieces Project Requirements MnichmP Density Optimum +4 95 min TEST PROBE M/D MOLSTURE WET DENSITY DRY DENSITY DENSTI'Y NO TEST LOCATION DEPTH No. (%) (pcf) (pcf) (% max) 1 Fill Water tap south side of building, 250' east, 6" 1 19.1 * 119.6 100.4 99 75' south from southwest corner, 1' below grade 2 Fill Water tap south side of building, 250' east, 6" 1 18.0* 119.1 100.9 100 75' south from southwest corner, final 3 Fill Water tap south side of building, 100' east, 6" 1 20.3 117.7 97.8 97 75' south from southwest corner, 1' below grade 4 Fill Water tap south side of building, 100' east, 6" 1 19.2* 120.8 101.3 100 75' south from southwest corner, final LIIvfITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Ow letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07SS Page 1 of 2 ..~ ".y.,.~~....y ~1~~ [Zeport No.: 265719 Project No.: 0612080 Client: Constructors & Associates PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY TEST ° NO TEST LOCATION DEPTH No. (%) (pct) (pct) (/o mag Fill 19.2* 116.1 97.4 96 5 Water tap south side of building, 100' west, 6" 1 80' south from southeast corner, 1' below grade Fill 20.0 116.2 96.8 96 6 Water tap south side of building, 100' west, 6" 1 80' south from southeast corner, final An asterisk (*) appears next to test results which do NOT meet the project specifications. on gi a ring Technician: Jered Sims Started: 1:45pm Finished: S:OOpm ._-_ Report Distribution: (1) Constructors & Associates Michael Cox, S T (1) City of Coppell Project Manager (I) City of Coppell LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not bePregro~uocf 2except in full without the written approval of Rone Engineering Services, Ltd. 07SS