ST9905-SP070216 (2)r #
1347 Mockingbird Iane, Dallas, Texas 75247
,~ (472) 647-6700, www.bci.com
Letter Of Transmittal
2/1/2007
3:47:OZPM
Report: 103931 Contains the Following Reports:
Report Description
• Submittal X2332 for Project: Bethel Road -Coppell
• Detailed Data for Submittal #2332
• Backup Data for Mix:8274 of Submittal X2332 for Project: Bethel Road -Coppell
• Seven Points Sand (December 2006).pdf attachment for Submittal X2332 for Project:Bethel Road -Coppell
• Cement Certificate (December 2006).pdf attachment for Submittal X2332 for Project:Bethel Road -Coppell
• Bridgeport 1 Stone (January 2007).pdf attachment for Submittal ;2332 for Project:Bethe] Road -Coppell
• Davavair 1000.pdf attachment for Submittal X2332 for Project:Bethel Road -Coppell
~ WRDA - Hycol.pdf attachment for Submittal #2332 for Project:Bethel Road -Coppell
{
LofREVIEWED O REJECTi
OREVISE AND ^ FUnNI~N !`;
RESUBMIT CORRECTED
Corrections or comments made on the shc~
drawings during this review do rrt rc!i;.•,~ c~n-
tractor from compliance with require,^ents of
the :' wwings and specifications. This check is
only i~r review of the general conformance with
tho d~sign concept of the project and gerertl
cc:~pliance with ih~ information given in the
contract documents. The contractor is responsi-
ble tor. Confrning ar,d ccrrelcaing 411 quantities
anc; c';~~ensicrc; sclcct;ng fo.5ricwticn processes
gad t~chniqu~s of conciruction, coordinating his
cr her e~ork vr;h th:,t of all other trades and
F~rforming a!I work in a sale and satisfactory
__ s 5TH
1
1992 - 2006 Digital Site Systems, Inc.
Pagel Quadret iService
SM
~
~ 1341 V'o'est Mockingbird Lane Dallas,Texas ?5247972.647.67[10 v,~vrw.txi.com
February 1, 2007
North Texas Bomanite
11107 Morrison Lane
Dallas, TX. 75229
Attn: Mr. Don Bruner
RE: Bethel Road - Coppell
Mix Code Numbers
8274
The attached concrete mix designs utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate are
proposed for use on the above referenced project for ready-mixed concrete to be furnished by TXI.
To ensure that the correct mix is delivered to your project, please order by the mix design number which
appears in the left hand corner of the mix design.
TXI certifies that the above mix designs, when ordered by specified design identity, and delivered by TXI, will
meet or exceed the indicated design strength at the designated age when tested in accordance with the
applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and
evaluated in accordance with applicable provisions of the ACI building code.
TXI would like to be uicluded on your mailing list to receive all test reports. ASTM C 94 entitles a
manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance.
Contact us if you have any questions or require any additional information. Please notify TXI of approval of the
proposed mix design prior to its use. Failure to notify us prior to first placement shall constitute acceptance. To
ensure that the proper mix design is ordered, please send a copy of this letter, after approval, to the above
referenced project to be used by the person ordering the concrete for this job.
The information contained in this submittal is confidential and the exclusive property of TXI. It cannot be
copied, duplicated or disclosed to third parties without the expressed written consent of TXI.
Sincerely,
TXI Operations, LP
.~-'
Victor H. Villarreal
Manager -Q.A./Q.C.
199? -?006 Digital Site Sysrems, Inc. Pao02 Quadrel iservice
SM
GENERAL NOTES
Pumping Notes:
1. 5" minimum diameter lines with no reduction to smaller lines.
2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as
possible.
3. Samples for slump and strength tests should be taken at discharge end of hose for strength
guarantee to be valid.
4. To prime pump lines, a minimum of 8.0 sack grout is recommended for lubrication. In the case of
strength concrete, equivalent strength grout should be used if the grout remains in the placement.
5. Pump mixes are based on minimum cement content pumped at ground level. As pump line
increases in length or height and/or layout configuration changes, mix design modifications may be
required to assure strength and pumpability at additional cost to the contractor.
6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air content
when loss occurs as a result of boom configuration or free fall discharge from hose. To ensure
minimum air loss when pumping, maintain a continuous flow of concrete through the entire length of
pipe and do not subject concrete to free fall.
7. The term "pumpable concrete" refers to concrete which is capable of being transported through an
apparatus which forces concrete to the placing position through a pipeline or hose as long as the
recommendations indicated above are followed. The term "pumpable concrete" does not relate to
concrete proportioned in a particular manner or containing a specific type of product.
Strength of lightweight mix designs valid provided strength specimens are air cured in accordance
with ASTM Test Method C 567-05, section 7.3 except as modified in section 8.1, alternative method,
ASTM Specification C 330-04.
Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees
Fahrenheit, TXI will guarantee the strength performance of the mix design(s) herein submitted up to a
maximum placement temperature of 100 degrees Fahrenheit using an ASTM C 494 Type D retarding
water-reducer, as long as the concrete is placed within 75 minutes from batch time. Unless otherwise
indicated, strength of plain concrete guaranteed up to a maximum placement temperature of 85
degrees Fahrenheit.
We are enclosing all available back up data for the referenced mix design(s). If the strength
infornlation is not available, or is insufficient, confirmation tests may have to be conducted by your
laboratory.
1992 - 2006 Digital Site Systems, Inc. paae3 Quadre] iService
SM
TXI PROPRIETARY AND CONFIDENTIAL
1341 Mockingbird Lane, Dallas, Texas 75247
~.._.. ~ , ~ ~ ._. e ; ..
(972 647-670u, www.txi.com
Customer: North Texas Bomanite Date Issued: February 1, 2007
Project: Bethel Road - Coppell Plant: 100
All DFW Plants
8274 1 6.OOSK ADMIX~'AEA 1"CS ,
As Required i
Description Admix. Weight (Ib)
Tvpe UII Cement S64
1" - #4 Crushed Stone 1840
Concrete Sand 1273
City Water 258
i Daravair 1000 O.S to 3.0 oz/cwt C+P
WRDA with Hycol 3.0 to S.0 oz/c~~t C+P I
Specified F'c : 4,000 psi @ 28 days TOTAL 3935 ~
Specified Slump: 2.00 To 4.00 in. Designed Unit Weight: 145.7 lbs./cu.ft.
I• Specified Air: 3.00 To 6.00 % Designed WiC + P Ratio: 0.46
Designed Air: ~ 4.5 % Designed Volume: 27.p0 cu.ft.
NOTES:
TXI has no knowledge or authority regarding where this mix is to be placed (if other than the defined use on
page 1), therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the
above designed mix parameters of compressive strength, water cement ratio, cement content, and air content,
are appropriate for the anticipated environmental conditions (ie. ACI-318 sections 4.1-4.3, and the local
Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and
Section 1.6.3., and per ASTM C-31.
Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the
right to adjust these dosages to meet the changes in jobsite demands.
This mix has been designed to meet the requirements of the documents received from the project, and/or your
verbal request. Aggregate weights may change depending on gradations or specific gravity of material.
Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or
dissemination without permission is a violation of federal criminal law.
COMMENTS:
1992 - 2006 Di;ital Site Systems; Inc. Page4 Quadrel iService
SM
txi
li41 Mockingbird Lang Dallas, Texas 75247
(972) 647.6700, www.txi.com
Date: 2/1/2007
Units : US
Mix Name: 8274
STRENGTH SUMMARY, Compression 5" x 12"
Streng ths
No. Of Avg Avg Avg 28 Avg Acc ACI3 18 Acce pt Std
Tests
------- Slumn Air
---------------- Day
--------- Age Req'd Age Dev
30
4.83 3.80 --
5290 ------------------
5290 4920 ----------
28 -------------
610
DETAILED STRENGTH, Compression 6" x 12"
Batch Date Plant dum p Air Strengths Acc Acc Age
~ Number
--------
---------------
----------- ~ 28 Day Acc Age Age Run Avg 3
346014
10/18/2006 -
123 ------
6.50 ------------
5.00 4660 ----------
4660 --------
28 ------------
346545 10/19/2006 123 4.50 5240 5240 28
348709 10/23/2006 150 4.00 4890 4890 28 4930
349737 10/24/2006 123 6.00 5.00 5210 5210 28 5110
349488 10/24/2006 123 5.25 4.40 4460 4460 28 4850
351611 10/27/2006 123 5.00 5.00 4820 4820 28 4830
353633 10/31/2006 135 5.50 4.70 6100 6100 28 5120
355261 11/1/2006 150 4.00 3.50 5400 5400 28 5440
356613 11/3/2006 123 6.00 5210 5210 28 5570
340856 11/6/2006 150 3.50 3.70 6190 6190 28 5600
739253 11/6/2006 150 6.25 2.80 5620 5620 28 5670
341979 11/9/2006 150 5.00 3.40 5840 5840 28 5880
361803 11/13/2006 123 5.75 4.30 4760 4760 2B 5410
344633 il/13/2006 150 4.00 3.50 4870 4870 28 5150
363136 11/14/2006 144 4.25 2.60 5990 5990 28 5210
363462 11/15/2006 123 5.50 4.70 5590 5590 28 5480
363636 11/15/2006 150 5.00 3.50 5300 5300 28 5630
364785 11/16/2006 144 5.00 2.50 6200 6200 28 5690
365998 11/17/2006 144 6.25 2.60 5010 5010 28 5500
366603 11/20/2006 123 6.50 5.70 4680 4680 28 5300
368115 11/21/2006 150 2.25 3.90 5830 5830 28 5170
358530 11/22/2006 123 5.75 5.20 5040 5040 28 5180
369811 11/27/2006 144 2.50 4.10 6020 6020 28 5630
370566 11/28/2006 144 4.50 2.10 5620 5620 28 5560
371583 11/29/2006 146 3.00 4.20 5450 5450 28 5700
371324 11/29/2006 150 5.50 4420 4420 28 5160
371311 11/29/2006 150 5.50 4.00 4310 4310 28 4730
373674 12/5/2006 146 1.50 3.30 6610 6610 28 5110
375776 12/8/2006 140 4.75 2.60 4710 4710 28 5210
379469 12/14/2006 144 5.00 2.60 4800 4800 28 5370
1992 - 2006 Digital Site Systems, Inc. pa~25
t ,
Quadrel iService
SM
f
Seven
Points
Sand 8~
Gravel
Quality-Depend ability-Integrity
~ ~
Date: December 5, 2006
From: Tom Gaedtke
Re: Sieve Analysis, November 3 through November 30, 2006
TXDOT / ASTM SIEVE ANALYSIS tRETAINED)
It~aterial P,etained /Sieve Mesh Size
Plant # 1
weea<
Ending
rcneness
Mod utrts
11/3 3.6 18.9 30.5 43.D ! 78.9 ~ 97.8 ! 99.5 ` 2 7Z
11110 6.6 23.0 36. Z 50.2 84.3 98.4 ! 99.4 i 2.98
11117 ~ 4 5 17.8 28.9 40.7 i 78.4 87.6 99.2 2.58
r i 1125 4.6 i 18 D 30.4 41.8_ ~ 77.8 97.2 I _
99.0 2.70
rrontbiyAv~ ; 4.8 _19,4 i 31.5 ___L _ 43.9 __79.8 95.2_ j_ _ 99 3 2.75 __,
Plant # 2
These numbers represent a weekhy average of a[I tests performed.
PO Box 43752 Seven Points, TX 75924 903-488-4526 Office 903-498-4893 Fax
A'1EDL~THtAN CEMENT
245 Ward Road • Midlothian,Texas 75065 • 472.775.3449 - www.txi.com
f
Sin Number: Car Number: Tons:
Sample Date: December-loos Monthly Average
r
SPECIFICATIONS
Portland Cement
Type Uii (Low Alkali)
A.S.T.M C150-05
Spec. Test Spec. Test
Chemical Requirements: Limit Result Physical Requirements: Limit Result
Air Content, Volume, {%} 12 max 8
AI203, (%} 6.0 max 4.5 Fineness (Blaine), (m2/kg} 280 min 346
Fe203, (%) 6.0 max 3.7 Autoclave Expansion, {%) 0.80 max -0.02
MgO~ (%} f 6.0 max 1.2 Time.nf Setting: ~
S03, (%) 3.0 max 2.7 Vicat initial set, minutes 45 min 1 t1
Loss on Ignition, {%} 3.0 max 2.2 375 max t i t
Insoluble Residue, {%} 0.75 max 0.28 Gillmore initial set, (minutes} 60 min 177
C3A, {°;°} 8 max 6 Gillmore final set, (minutes} 600 max 283
Limesione, (%} 5.0 max 2.9 Compressive strengths, (Mpa)
CaC03 in limestone, (%) 70 min 98 3 days 7.0 min 27.0
7 days 12.0 min 33.6
Spec. Test Compressive strengths, (psl}
Optional Chemical Requirements: Limit Resuit 3 days 1740 min 3917
Total Alkalies (Na20 equiv.}, {%} 0.60 max 0.50 7 days 2760 min 4869
"Nof Appfcable.
We certify that the above described cement, at the time of shipment, meets
the chemical and physical requirements of the ASTM C 150 specification.
Qualit anager
Subscribed and sworn to before me on this date: 1/9/2007
Notary
`~~~A~Y nyeG,' R 6 ! ~ R. ~ E:r{ ~ `i: is
~, omrr ~~s, ~sp~rE
NSF,
Certified to
NSFJANSI 61
TXI corp.
BRIDGEPORT STONE PLANT TECHNICAL SERVICES LAB
P.O. BOX 487 PHONE: 972-647-7232
BRIDGEPORT, TEXAS 76426 FAX: 972-647-7244
_.
...,, ~ .....
~ - ~ ~ _
~
tee. _.W
. ,. ,. _, ~.... a .. .. ..,..
-^ ~~ x _ ~~u.»m,.....~,;s~~+. Adm. s.:~~M..._._.~,.,;::
.- .!r'. s..~. ~~ 3?~r*^+~, _mr°.+ w:,....~....
.av~,. ..s ...x..._ wo- _aem~l„:..3 'k-~a.~~.,.~~.d:v,..~..
DATE January 9, 2007
COMPANYINAME
MATERIAL 1" - #4 CLASS A TxDOT ITEM 421 GRADE 4
F .. ___ ~-...
- + _
- w:... -
....
..... » .~..
TEST RESULTS
SIEVE 51ZE WT. RETAINED % RETAINED SPECIFICATION
U_S. METRIC
1112" 37.5mm 0.0 0.0% 0
1" 25.Omm 0.2 0.7% 0 5
314" 19.0 mm 5.1 18.3%
1/2" 12.5mm 14.5 52.0% 40 , 75
318" 9.5mm 22.9 82.1
#4 4.75mm 26.3 94.3% 90 100
#8 2.36mm 27.5 98.6% 95 100
TOTAL WEIGHT 27.9
...._...w..~ ...._ _. _ ~ ~ ,: .. ~..~..., ..,.,..,
SPECIFIC TEST RESl1LTS
SPECIFIC GRAVITY 2.65
UNIT WEIGHT
ABSORPTION 1.1 DRY LOOSE 94.2 LB./ CF.
DRY RODDED 103.2 LB./ CF.
LA ABRASION 30
DECANT 0.6
SODIUM SOUNDNESS 3
MAGNESIUM SOUNDNESS 7
,... Y ~,
Skeet Caruthers
TXI REPRESENTATIVE
Grace Construction Products
W.R. Grace & Co. -Conn.
4323 Crites Street
Houston, TX 77003
713-223-8353
www.graceconstruction.com
6/15/200'5
Victor H. Villarreal
TXI Operations, Lp
1341 W. Mockingbird Lane
Dallas, Texas 75247
Project Name: All Projects
Product Selected: Daravair0 1000
This is to certify that the Daravair® 1000, a(n) Air-Entraining Agent, as manufactured and supplied by
Grace Construction Products, W.R. Grace & Co. -Conn., is formulated to comply with the Specifications
for Chemical Admixtures for Concrete, ASTM: C260 AASHTO: M154.
Daravair® 1000 does not contain calcium chloride or chloride containing compounds as a functional
ingredient. Chloride ions may be present in trace amounts contributed from the process water used in
manufacturing.
The foregoing is in addition to and not in substitution for our standard Conditions of Sale attached.
Thomas M. Greene
South Western Region Technical Services Manager
Grace Construction Products
W.R. Grace & Co. -Conn.
4323 Crites Street
Houston, TX 77003
713-223-8353
www.graceconstruction.com
f
6/15/2005
Victor H. Villarreal
TXI Operations, Lp
1341 W. Mockingbird Lane
Dallas, Texas 75247
Project Name: All Projects
Product Selected: WRDA® with Hycol®
This is to certify that the WRDA® with Hycol®, a(n) Water Reducer, as manufactured and supplied by
Grace Construction Products, W.R. Grace & Co. -Conn., is forrnGlated to comply with the Specifications
for Chemical Admixtures for Concrete, ASTM: C494, Type A, D AASHTO: M194, Type A, D.
WRDA® with Hycol® does not contain calcium chloride or chloride containing compounds as a functional
ingredient. Chloride ions may be present in trace amounts contributed from the process water used in
manufacturing.
The foregoing is in addition to and not in substitution for our standard Conditions of Saie attached.
/ _ -~-~ .~
Thomas M. Greene
South Western Region Technical Services Manager
.~'
::::~>
.;. , ,..
:::
® PAVING COMPANY
P.O. Box 270040 Dallas, Texas 75227-0040 Telephone (972) 289-0723 Fax (972) 216-5637
DATE: February 8, 2007
TRAN SYSTEMS
3010 LBJ FREEWAY
SUITE 900
DALLAS, TX 75234
ATTN: Garry D. Kraus, P.E.
PROJECT: BETHEL RD
SUBMITTAL:
TXI CONCRETE MIX DESIGNS - # 8274 6 SK 4000 PSI
TO BE USED BY NORTH TEXAS BOMANITE FOR STAMPED COLORED CONCRETE
PLEASE REVIEW THE SUBMITTAL OR SUBMITTALS AND RETURN 4 COPIES WITH
SIGNATURE AND DATE WITH APPROVAL OR REJECTION.
LANCE SMITH
PROJECT ADMINISTRATOR
-02 :~ =~ ~----------
DATE:
~ata~ialced 1974